Chapter 7 Installing Internal Options
Fibre Channel Controller
The CD-ROM drive unit may not be recognized at the next startup after installation of Fibre Channel
Controller (PG-FC106) in a Windows Server 2003 server. Perform the following steps, then it will be
recognized.
1
Click [Start] → [Administrative Tools] → [Computer Management].
2
Click [Device Manager].
3
From the device list in the right pane of the window, select [DVD/CDROM
drive].
4
Select [Scan for Hardware Changes] from the [Action] menu.
IB HCA Card
When installing an IB HCA Card (PG-HSC101), set the switches on the card as follows. This card is not
supported in Windows.
Switch No.
SW1
SW2
Remote Service Board
• Before installing a remote service board
For preparation and procedures for installing a remote service board, refer also to the manual
supplied with the board.
182
table: IB HCA Card Switch Settings
1
2
3
ON
OFF
ON
OFF
OFF
OFF
• Do not connect the remote service board AC adapter until you finish installing
the remote service board and close the top cover of the server. Doing so may
cause a device failure, fire, or electric shock.
• When replacing remote service boards or adding other optional devices,
unplug the power cable of the remote service board AC adapter from the
outlet.
Failure to do so may cause a device failure, fire, or electric shock.
• When the server is installed in an upper position in the rack, fasten the AC
adapter in the rack. If the AC adapter unit is suspended, excessive force can
be put on the cable, causing failures.
Setting
4
5
6
-
-
OFF
OFF
OFF
OFF
7
8
-
-
OFF
OFF