Fujitsu PRIMERGY RX200 S2 User Manual page 194

Hide thumbs Also See for PRIMERGY RX200 S2:
Table of Contents

Advertisement

Chapter 7 Installing Internal Options
5
Install the internal hard disk unit into the server.
With the handle on the internal hard disk unit in the raised position, insert the unit all the way into
the bay.
Handle
6
Push down the handle on the internal hard disk unit until it clicks into position.
Handle
■ How to Remove the Internal Hard Disk Unit
1
Open the rack door.
"1.4.1 Opening the Rack Door" (pg.28)
2
Turn off the server and peripheral devices, then unplug the power cables from
the server.
"1.4.3 Turning Off the Server" (pg.32)
3
Touch a metal part of the server to discharge static electricity.
4
Remove the internal hard disk unit.
With the front tab of the internal hard disk unit pressed, turn the handle upward (1) and pull the
hard disk unit towards you (2). To remove the internal hard disk unit, use both hands to pull it out.
Handle
2
194
1
Tab

Advertisement

Table of Contents
loading

Table of Contents