Hard disk drives / solid state drives
6.3

Removing a 2.5-inch HDD/SSD module

Customer Replaceable Units (CRU)
Average task duration: 5 minutes
V
Only applicable for removing non-defective HDD/SSD modules:
Ê Set the drive to "Offline" via the software (RAID controller
configuration software), before removing an HDD/SSD module that is
not defective.
6.3.1

Required tools

Preliminary and concluding steps: tool-less
Main steps: tool-less
6.3.2

Preliminary steps

Perform the following procedures:
Ê Only applicable for removing intact HDD/SSD modules (for example:
preventive exchange in case of S.M.A.R.T):
Ensure that the HDD/SSD module to be removed is not combined into a
RAID array. If the drive is part of a RAID array, you first need to delete the
array using ServerView RAID Manager.
V
CAUTION!
All data on all HDDs/SSDs in the array will be lost! Be sure to back up
your data before deleting a RAID array.
I
For further information, please refer to the "ServerView Suite RAID
Management" user guide, available online.
"Opening the rack door" on page 52
Ê
108