Replacing The Server Blade - Fujitsu Primergy BX920 S4 Upgrade And Maintenance Manual

Primergy bx920 s4 server blade upgrade and maintenance manual
Hide thumbs Also See for Primergy BX920 S4:
Table of Contents

Advertisement

Server blade
11.1

Replacing the server blade

Field Replaceable Units (FRU)
Average hardware task duration: 50 minutes
Average software task duration: 10 minutes
I
Ensure to note down your current network settings before replacing the
server blade.
When replacing server blade, network configuration settings in the
operating system will be lost and replaced by default values. This applies
to all static IP address and LAN teaming configurations.
Ê If possible, save the BIOS settings as described in section
settings" on page
Ê If possible, save the iRMC settings as described in section
settings" on page
Ê Exit all applications and shut down the server blade correctly. If your
operating system has not switched off the server blade, press the on/off
button on the server blade control panel.
Ê If applicable, remove the HDD/SSD modules from the server blade, see
section
"Removing the 2.5-inch HDD/SSD module" on page
I
Ensure to take note of the HDD/SSD modules mounting positions for
reassembly.
Ê Remove the server blade from the system unit, see section
server blade" on page
Ê Open both server blades, see section
page
56.
Ê Remove the heat sinks from the defective server blade, see section
"Handling processor heat sinks" on page
Ê Remove the processors from the defective server blade and install it into the
new server blade, see section
page
198.
252
65.
65.
54.
"Upgrading or replacing processors" on
Upgrade and Maintenance Manual
"Opening the server blade" on
201.
"Saving BIOS
"Saving iRMC
109.
"Removing a
BX920 S4