Removing The Tpm - Fujitsu Primergy BX920 S4 Upgrade And Maintenance Manual

Primergy bx920 s4 server blade upgrade and maintenance manual
Hide thumbs Also See for Primergy BX920 S4:
Table of Contents

Advertisement

Ê Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify
settings, refer to the "D3142 BIOS Setup Utility for PRIMERGY
BX920 S4" reference manual available online.
Ê If applicable, open the rack door as described in section
door" on page
Ê Locate the desired server blade as described in section
defective server blade" on page
Ê Shut down the server blade as described in section
server blade" on page
Ê Remove the server blade from the system unit as described in section
"Removing the server blade from the system unit" on page
Ê Open the server blade as described in section
on page
56.

10.3.2.3 Removing the TPM

Ê Remove the system board as described in section
board" on page
Ê Lay the system board on a soft, antistatic surface with its component side
facing down.
Figure 99: Removing the TPM screw from the underside of the system board
Ê Locate the slotted lower end of the TPM screw (see arrow).
Ê Carefully loosen the TPM screw using a thin slotted screw driver (e.g.
watchmaker's screw driver) or the dedicated TPM screw driver (Japanese
market).
BX920 S4
52.
53.
245.
Upgrade and Maintenance Manual
System board components
45.
"Opening the server blade"
"Opening the rack
"Locating the
"Shutting down the
55.
"Removing the system
233