Locating The Defective Server Blade - Fujitsu Primergy BX920 S4 Upgrade And Maintenance Manual

Primergy bx920 s4 server blade upgrade and maintenance manual
Hide thumbs Also See for Primergy BX920 S4:
Table of Contents

Advertisement

4.1.2

Locating the defective server blade

Figure 3: ID button and indicator on front panel
When working in a datacenter environment, switch on the ID indicator on the
front panel of the server blade for easy identification.
Ê Press the ID button on the front panel (1), use the management blade web
interface, or use the ServerView Operation Manager user interface to switch
on the ID indicator (2).
I
For further information, refer to the "ServerView Suite Local Service
Concept (LSC)" manual available online at
(EMEA market) or
(Japanese market).
Ê When using management blade web interface to toggle the ID indicator,
open the Components - System - Server Blades - Server Blade-x menu for the
desired server blade, and press the Locate button in the server blade status
frame.
Ê When using ServerView Operations Manager to toggle the ID indicator,
choose Single System View and press the Locate button.
Ê Remember to switch off the ID indicator after the maintenance task has been
concluded successfully.
BX920 S4
http://jp.fujitsu.com/platform/server/primergy/manual/
Upgrade and Maintenance Manual
Basic hardware procedures
http://manuals.ts.fujitsu.com
45