Item
No.
08
09
10
11
12
13
14
15
16
17
18
19
20
2 - 614
Item
Description
Specifies the timer value in 1/100ths
T308
of a second of the timer to be started
when REL is sent.
Specifies the timer value in 1/100ths
T309
of a second upon data link
disconnection.
T310
Specifies the timer value in 1/100ths
of a second of the timer to be started
when CALL PROC is sent.
Specifies the timer value in 1/100ths
T312
of a second of the timer to be started
when SETUP is sent or re-sent on
broadcast data link. This timer is only
valid for Network side use only.
Specifies the timer value in 1/100ths
T313
of a second of the timer to be started
when connection request is sent.
Valid range 1 ~ 4 seconds in 1 second
increments. Value of 0 indicates timer
not used.
Specifies the timer value in 1/100ths
T314
of a second of the timer to be started
when message segment is received.
Specifies the timer value in 1/100ths
T316
of a second of the timer to be started
when RESTART is sent.
T317
Specifies the timer value in 1/100ths
of a second of the timer to be started
when RESTART is received.
Specifies the timer value in 1/100ths
T318
of a second of the timer to be started
when RES is sent. This timer is valid
for user side use only.
Specifies the timer value in 1/100ths
T319
of a second of the timer to be started
when SUSPEND is sent. This timer is
valid for user side use only.
Specifies the timer value in 1/100ths
T320
of a second when B-channel access:
connection is received, or D-channel
access: DL-ESTABLISH confirmation
or indication is received.
Specifies the timer value in 1/100ths
T321
of a second of the timer to be started
when STATUS ENQ is received.
T322
Specifies the timer value in 1/100ths
of a second upon D-channel failure.
Input Data
1~254 (sec)
1-254 (sec)
0~180 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
(T317+1)~254 (sec)
1~(T316-1)
1~254 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
1~254 (sec)
Program 81 : Basic Hardware Setup for Trunk
UNIVERGE SV8100
Default
4 (sec)
90 (sec)
180 (sec)
6 (sec)
4 (sec)
4 (sec)
120 (sec)
60 (sec)
4 (sec)
4 (sec)
30 (sec)
30 (sec)
4 (sec)