System Alarm Setup; Table 2-20 Description Of Alarm - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
UNIVERGE SV8100
Level:
IN
Description
Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm is displayed to a multiline terminal and whether or not the alarm information
is reported to the pre-defined destination.
Input Data
Alarm
Type
Report
No.
1
2
0
PKG Initialize
Error.
2
0
PKG Mount-
2
ing Error
Programming Manual
Program 90 : Maintenance Program
Alarm Number
Item
No.
01
Alarm Type
02

Table 2-20 Description of Alarm

Name
Content of Alarm
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.

90-10 : System Alarm Setup

Item
Input Data
0 = Not Set
1 = Major Alarm
2 = Minor Alarm
0 = Not Report (No autodial)
Report
1 = Report (autodial)
Cause
1. PKG not inserted
1. Insert PKG firmly.
firmly.
2. Insert PKG firmly.
2. PKG was
3. Delete slot
removed, but not
information in
reinserted firmly.
PRG 90-05 and reinsert
3. Old PKG data
the PKG.
still reported due to
no initialization.
1.The package is
1.Please insert the
half.
package firmly.
2.The package is
2.Please try again after
out of order.
initializing the system
data once when LED
doesn't blink normally.
3.Exchange of
packages.
Issue 1.0
001~100
Action
Recovery
Upon
initialization,
the PKG is
recognized.
When the unit
is
reconfirmed,
the error is
recovered.
Alarm
Status
ERR
REC
ERR
REC
2 - 705