84-24 : DT700 Multiline CODEC Basic Information Setup

Level:
IN
Description
Use Program 84-24 : DT700 Multiline CODEC Basic Information Setup to set the
codec of each type of DT700 Multiline Telephone.
Input Data
Item
No.
01
02
03
04
05
06
07
08
09
10
2 - 680
Program 84 : Hardware Setup for VoIP
Type
Item
Number of G.711 Audio Frames
Input the amount of audio in the packets
when using the G.711 CODEC.
--- Not Used ---
G.711 Type
This decides the G.711 type. In North
America, typically u-law is used.
G.711 Jitter Buffer Min
G.711 Jitter Buffer Average
G.711 Jitter Buffer Max
Number of G.729 Audio Frames
--- Not Used ---
G729 Jitter Buffer Min
G729 Jitter Buffer Average
UNIVERGE SV8100
1 = Type 1
2 = Type 2
3 = Type 3
4 = Type 4
5 = Type 5
Input Data
1~4
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
0 = A-law
1 = u-law
0~160ms
0~160ms
0~160ms
1~4
1 = 10ms
2 = 20ms
3 = 30ms
4 = 40ms
0~270ms
0~270ms
Program 84 : Hardware Setup for VoIP
Default
2
1
20
40
80
2
20
40

Hide quick links: