NEC Univerge SV8100 Programming Manual page 742

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Digitcom Canada Inc. Need Support? Call 1-866-667-8357 Visit us at: www.digitcom.ca
Issue 1.0
Alarm
Type
Report
No.
13
0
0
Charge
Management
Link Error
14
0
0
LAN Link
Error
15
0
0
Network Keep
Alive
16
0
0
SMDR Link
17~28
--- Reserved ---
29
0
0
Charge
Management
Buffer full
30
2
0
SMDR Buffer
full
31~34
--- Reserved ---
2 - 708
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The link with the charge
management device came
off.
The link with LAN on
CD-CP00-US came off.
1. The network connection
has been cut.
2. Network Keep Alive
restoration.
3. Response notification on
network Keep Alive.
The temporary buffer for
the charge management in
main device was
overflowed, and a part of
unoutput charge data
disappeared because it
was not able to output the
charge management data.
The temporary buffer for
SMDR in main device was
overflowed, and a part of
unoutput SMDR data
disappeared because it
was not able to output
SMDR data.
Cause
Action
1. Problem of
1. It is confirmed that
wiring to connect
there is no problem in
main device with
wiring to connect a
charge
main device with the
management
charge management
device.
device. (Whether ping
2. Problem of PC.
passes for LAN
connection is
confirmed.)
2. Restart the charge
management software.
3. Reboot PC, and start
the charge
management software.
• LAN cable
Confirm the operation
defective.
of LAN connector, LAN
• Connected HUB
cable, and HUB again.
broken.
• Defect of
CD-CP00-US
• LAN cable is
Confirm whether the
defective.
defect is on the Network
• Net side trouble.
side.
• Packet block by
Confirm the settings of
firewall.
HUB and the router,
• Repetition of IP
etc.
address.
1. The charge data
1. Please print and
is printed and not
delete the charge data
deleted at the
at the simple charge
simple charge
management.
management.
2. Please connect the
2. The charge data
charge management
is not output to PC
software for the charge
for the charge
management software
management
and output the charge
software.
data.
1. Problem of
1. Please confirm
wiring to connect
whether there is
main device with
problem in wiring to
PC.
connect a main device
2. Problem of PC.
with PC.
2. Please execute the
reactivation of PC.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
When the
ERR
connection
REC
returns
normally, the
error is
recover.
When the
ERR
connection
REC
returns
normally, the
error is
recover.
When the
ERR
connection
REC
returns
WAR
normally, the
error is
recovered.
When the
ERR
output is
REC
restarted, the
error is
recovered.
However, the
charge
management
data after the
error occurs is
not recorded.
When the
ERR
output is
REC
restarted, the
error is
recovered.
However, the
SMDR data
after the error
occurs is not
recorded.