<Attachment Procedure>
1) Fold the second side CIS flat cable as shown in the figure below.
Mountain fold
Valley fold
Reinforcing tape
The edge of the reinforcing tape
2) Connect the second side CIS flat cable to the second side CIS unit.
3) Pass the second side CIS flat cable through the upper document chute ASSY and the
lower document chute ASSY.
Second side CIS
flat cable
922.5 mm
101 mm
45°
Second side CIS flat cable
Fig. 3-41
Second side CIS unit
Upper document chute ASSY
Lower document chute ASSY
Fig. 3-42
3-51
102 mm
CIS side
Electrode