Peripheral Installation

SMDR Printout Examples

Note
Direct Inward System Access (DISA) Exchange Lines
Note
Example 1–Ring, No Answer DISA Call
Call Sequence A
Example 2–DISA Internal Station Call
Call Sequence B
Note
6-38
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
SMDR printout "time of day" and month/day/year (MM/DD/YY) is the same as the
system clock time/date set by the station connected to Port 000. SMDR MM/DD/YY
prints out each time 50 call records are generated and at midnight each day.
DISA station calls print out as MSS or DISA.
Outside caller rings Exchange line 003. (Exchange line 003 is programmed as a
DISA line.)
Line 003 returns internal dial tone to caller after one or two ring cycles (5~6
seconds).
Caller does nothing. Station 10 rings but is not answered.
After 32 seconds, call is disconnected.
Printout A prints after disconnect at 4:59.
Printout A: 003 MSS 04:59 00:00;32 00;06
Outside caller rings Exchange line 003. (Exchange line 003 is programmed as a
DISA line.)
Line 003 returns intercom dial tone to caller after two ring cycles (5~6 seconds).
Caller dials 13.
After 48 seconds from start of call, station 13 answers.
Printout B (line 1) prints after station 13 answers the call at 4:32.
Printout B (line 2) prints out after station 13 clears the call down at 4:33.
MSS will not print if the call is answered before the threshold time set in
Program 60-2.
Printout B:
003 MSS 04:32 00:00;48 00;05 13
003
13 04:33 00:00:15