Emc Compliance - Toshiba Strata DK40 Installation & Maintenance Manual

Hide thumbs Also See for Strata DK40:
Table of Contents

Advertisement

DK40 Configuration
Type of Circuit
(EN60950
Classification
SELV
SELV
SELV
Any peripheral apparatus connected to the above ports must have the same EN60950
classification. ie.
The system must plugged into a switched 3 pin mains socket, this socket must be installed in
accordance with 16th edition of the IEE wiring regulations, aka BS7671:1992.
Environmental Installation details.
The Strata DK40 is designed to work within the following environmental conditions:
Notes to Users: Safety Approval
Toshiba Information System (UK) Ltd declare that the Strata DK40 complies with the EEC's
LVD directive, (Directive No. 73/23/EEC). The product has been assembled and found to
comply with EN60950:1997. The notes listed below form part of the products compliance
with the aforementioned European Norm.
The system, TCOU1F unit, must be earthed. The earth connection must be hardwired to a
main distribution point. The main cabinet must be earthed.

EMC Compliance

Toshiba Information Systems (U.K.) Ltd declare that the Strata DK40 complies with the
EEC's EMC directive, Directive No. 89/366/EEC as amended by directive 92/31/EEC. The
product has been assessed and found to comply with the following generic standards, in the
present absence of any product specific standards:
EN55022:1987
EN50082-1:1992
The notes listed below form part of the products compliance with the aforementioned Euro-
pean Norm.
To ensure EMC compliance the system must installed in accordance with the instructions in
the "Installation and Maintenance" manual.
1-14
Refer to the Strata DK40 Programming Manual or DK Library CD-Rom for more details.
Port Location
PIOU2D
PIOUS2D
EKT and DKT
SELV ports must only be connected to SELV type ports.
TNV ports must only be connected to TNV type ports.
Operating temperature 0
Humidity 10% to 80%
Port Description
Contains various ports for connection of audio paging
amplifiers, dry relay contacts to control external
equipment, two V24 ports for connection to PCs or
printers.
Contains various ports for connection of audio paging
amplifiers, dry relay contacts to control external
equipment, two V24 ports for connection to PCs or
printers.
Headset ports on any of the range of key telephones.
o
C to 40
o
C
Strata DK40 I&M Manual Spring 1999