Commissioning
9.3 Axis control panel
Area
Element
Modify
Position
Distance
Target position
Velocity/
Velocity setpoint
Acceleration
Deceleration
Jerk
"Start" button
"Forward" button With the "Forward" button, you start a motion in the positive direction according to the
"Backward"
button
"Stop" button
Axis status
Drive ready
Error
Enabled
Homed
More
Active errors
"Confirm" button With the "Confirm" button, you acknowledge pending errors.
Current values
Position
Velocity
Note
No transfer of the parameters
The configured parameter values are discarded when master control is returned. Transfer
the values as needed into your configuration.
If you change configuration values with the axis control panel during operation, they have no
effect on the operation of the axis control panel.
204
Description
The "Control" area displays the parameters for traversing with the axis control panel
according to the selected operating mode.
Position to which the axis is homed.
(Homing and set home position modes only)
Distance the axis is traversed.
(Relative positioning mode only)
Position to which the axis is traversed.
(Absolute positioning mode only)
Velocity or speed at which the axis is traversed.
Default: 10% of the default value
(Velocity specification/Default speed, Jog and Positioning modes only)
Acceleration with which the axis is traversed.
Default: 10% of the default value
Deceleration with which the axis is traversed.
Default: 10% of the default value
Jerk with which the axis is traversed.
Default: 100% of default value
With the "Start" button, you start a job according to the selected operating mode.
selected operating mode.
With the "Backward" button, you start a motion in the negative direction according to
the selected operating mode.
With the "Stop" button, you cancel a job or stop the axis.
The "Axis status" area displays the status of the axis and the status of the drive.
The drive is ready to execute setpoints.
An error has occurred at the technology object.
The technology object is enabled. The axis can be controlled with Motion Control
instructions.
The technology object is homed.
With the "More" link, you display the "Technology object > Diagnostics > Status and
error bits" dialog.
The error that occurred most recently is displayed in the "Active errors" text box.
The "Current values" area shows the actual values of the axis.
Actual position of the axis
Actual velocity of the axis
S7-1500 Motion Control V13 Update 3