Warningword Tag (External Encoder); Internaltotrace Tags (External Encoder) - Siemens SIMATIC S7-1500 Function Manual

Update 3
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

A.3.13

WarningWord tag (external encoder)

The <TO>.WarningWord tag indicates pending warnings at the technology object.
Notes on the evaluation of the individual bits (e.g. bit 11, "FollowingErrorWarning") can be
found in the Evaluating StatusWord, ErrorWord and WarningWord (Page 175) section.
Tag
Legend (Page 358)
Tag
Data type
Warning-
DWORD
Word
Bit 0
-
Bit 1
-
Bit 2
-
Bit 3
-
Bit 4...
-
Bit 31
A.3.14

InternalToTrace tags (external encoder)

The tag structure <TO>.InternalToTrace.<tag name> contains no application-relevant data.
This tag structure is internally used.
Tags
Legend (Page 358)
Tag
InternalToTrace.
Id
Value
S7-1500 Motion Control V13 Update 3
Function Manual, 07/2014, A5E03879256-AC
Values
W
-
RON
-
-
-
-
-
-
-
-
-
-
Data type
Values
ARRAY [1..4]
OF STRUCT
DINT
-
LREAL
-
A.3 Tags of the technology object external encoder
Description
Reserved
"ConfigurationFault"
Configuration error
One or several configuration parameters are adjusted internally.
Reserved
"CommandNotAccepted"
Command cannot be executed.
A Motion Control command cannot be executed, because neces-
sary preconditions are not met.
Reserved
W
Description
DIR
-
RON
-
Appendix
367