659
LED Cond IN 4
660
LED 11 Red
660
LED Cond IN 5
661
LED 11 Grn
661
LED Cond IN 6
662
LED 12 Red
662
LED Cond IN 7
663
LED 12 Grn
663
LED Cond IN 8
664
LED 13 Red
664 to
--
685
665
LED 13 Grn
666
LED 14 Red
667
LED 14 Grn
668
LED 15 Red
669
LED 15 Grn
670
LED 16 Red
671
LED 16 Grn
672
LED 17 Red
673
LED 17 Grn
674
LED 18 Red
675
LED 18 Grn
676
Function Key 1
677 to
Function Key 2 to
685
Function Key 10
686 to
--
699
700 to
Output cond. 1 to
763
Output cond. 64
764 to
--
799
764
LED 1 Red Condit
765
LED 1 Grn Condit
766
LED 2 Red Condit
767
LED 2 Grn Condit
768
LED 3 Red Condit
769
LED 3 Grn Condit
770
LED 4 Red Condit
Description
Hardware version J - Assignment of signal to drive
output Function Key LED 4
Hardware version K - Programmable Red LED n° 11
Hardware version J - Assignment of signal to drive
output Function Key LED 5
Hardware version K - Programmable Green LED n° 11
Hardware version J - Assignment of signal to drive
output Function Key LED 6
Hardware version K - Programmable Red LED n° 12
Hardware version J - Assignment of signal to drive
output Function Key LED 6
Hardware version K - Programmable Green LED n° 12
Hardware version J - Assignment of signal to drive
output Function Key LED 7
Hardware version K - Programmable Red LED n° 13
Hardware version J – Unused
Hardware version K - Programmable Green LED n° 13
Hardware version K - Programmable Red LED n° 14
Hardware version K - Programmable Green LED n° 14
Hardware version K - Programmable Red LED n° 15
Hardware version K - Programmable Green LED n° 15
Hardware version K - Programmable Red LED n° 16
Hardware version K - Programmable Green LED n° 16
Hardware version K - Programmable Red LED n° 17
Hardware version K - Programmable Green LED n° 17
Hardware version K - Programmable Red LED n° 18
Hardware version K - Programmable Green LED n° 18
Hardware version K - Programmable Function key n° 1.
In 'Normal' mode it is high on key press and in 'Toggle'
mode remains high/low on single key press
Hardware version K - Function key n° 2 to
Function key n° 10
Unused
Input to Relay Output Conditioner
Hardware version J – Unused
Hardware version K - Assignment of signal to drive
output LED 1 red - To drive LED1 Yellow DDB 764 and
DDB 765 must be driven at the same time
Hardware version K - Assignment of signal to drive
output LED 1 green
Hardware version K - Assignment of signal to drive
output LED 2 red
Hardware version K - Assignment of signal to drive
output LED 2 green
Hardware version K - Assignment of signal to drive
output LED 3 red
Hardware version K - Assignment of signal to drive
output LED 3 green
Hardware version K - Assignment of signal to drive
output LED 4 red
P44x/EN PL/Hb6
(PL) 6-21
Source
PSL
SW
PSL
SW
PSL
SW
PSL
SW
PSL
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
SW
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL