Programmable Logic
MiCOM 40 Agile P442, P444
Ordinal
English Text
1042
Force 3P Trip
676
Function Key 1
677 to
Function Key 2 to
685
Function Key 10
174
General Alarm
472
GOOSE IED Absent
1034
I A/R 1p In Prog
1035
I A/R 3p In Pr.
1036
I A/R Close
1037
I A/R Reclaim
181
I^ Lockout Alarm
180
I^ Maint Alarm
1106
I<1 Block
429
I<1 Start
1108
I<1 Timer Block
431
I<1 Trip
1107
I<2 Block
430
I<2 Start
1109
I<2 Timer Block
432
I<2 Trip
301
I> Start Any A
302
I> Start Any B
303
I> Start Any C
Description
Three pole tripping only: If it is assigned to an opto
input in the PSL and energised, the DDB:'Force 3P
Trip' signal will force the internal single-phase
protection to trip three-poles (external order from
Main1 to Main2 (P44x)) – the next trip will be three-
pole.
Hardware version K - Programmable Function key n°
1. In 'Normal' mode it is high on key press and in
'Toggle' mode remains high/low on single key press
Hardware version K - Function key n° 2 to
Function key n° 10
Groupment of all alarms
Absence of GOOSE message from dedicated IED
One-pole external autoreclose cycle in progress: If it is
assigned to an opto input in the PSL and energised,
The DDB:'A/R 1P in Prog' will block the internal DEF
protection as it indicates that an external single-pole
autoreclose cycle is in progress.
Three-pole external autoreclose cycle in progress: If it
is assigned to an opto input in the PSL and energised,
the DDB:'A/R 3P in Prog' will inform the P44x about the
presence of an external 3P cycle. The data is useful in
the case of an evolving fault.
Circuit Breaker closing order from external autoreclose:
If it is assigned to an opto input in the PSL and
energised, the DDB:'A/R Close' can be linked with the
internal check synchronism condition to verify the
external CB close command.
External (opto input) autorecloser in progress: the
DDB:'I A/R Reclaim' signal will inform the protection
that an external reclaim time is in progress and will
initiate the internal TOR logic (it is possible to create a
dedicated PSL which would make it possible to use
this information extension in Zone 1 extension
schemes).
Broken current lockout alarm (2nd level): An alarm
Lock Out is issued when the maximum broken current
(2nd level) calculated by the monitoring function is
reached
Broken current maintenance alarm (1st level): An
alarm maintenance is issued when the maximum
broken current (1st level) calculated by the CB
monitoring function is reached (see setting: 'CB
monitor setup / I^ Maintenance')
Block phase undercurrent stage 1
Undercurrent stage 1 start
Timer block phase undercurrent stage 1
Undercurrent stage 1 trip
Block phase undercurrent stage 2
Undercurrent stage 2 start
Timer block phase undercurrent stage 2
Undercurrent stage 1 trip
Any overcurrent start for phase A
Any overcurrent start for phase B
Any overcurrent start for phase C
P44x/EN PL/Hb6
(PL) 6-41
Source
PSL (IN)
SW
SW
PSL (OUT)
PSL(OUT)
PSL (IN)
Autorecloser
PSL (IN)
Autorecloser
PSL (IN)
Autorecloser
PSL (IN)
Autorecloser
PSL (OUT)
CB
monitoring
PSL (OUT)
CB
monitoring
PSL (IN)
PSL
PSL (IN)
PSL
PSL (IN)
PSL
PSL (IN)
PSL
PSL (OUT)
Phase Overc.
PSL (OUT)
Phase Overc.
PSL (OUT)
Phase Overc.