GE MiCOM P40 Agile Technical Manual page 348

Hide thumbs Also See for MiCOM P40 Agile:
Table of Contents

Advertisement

P44x/EN PL/Hb6
(PL) 6-28
Ordinal
English Text
1079
DIST. Tim. Block
1080
Reset Lockout
1081
Reset All values
1082
Reset Latches
1083
Stub Bus Enable
1084
User Trip A
1085
User Trip B
1086
User Trip C
1087
ZSP Timer Block
1088
PAP TeleTrip CR
1089
PAP TeleT. Heath
1090
PAP Timer Block
1091
Reset Thermal
1092
Time Synch
1093
Select CS(NCIT)
1094
T1 Timer Block
1095
T2 Timer Block
1096
TZp Timer Block
1097
TZq Timer Block
1098
T3 Timer Block
1099
T4 Timer Block
1100
F<1 Timer Block
1101
F<2 Timer Block
1102
F<3 Timer Block
1103
F<4 Timer Block
1104
F>1 Timer Block
1105
F>2 Timer Block
1106
I<1 Block
1107
I<2 Block
1108
I<1 Timer Block
Description
Block distance element time delay
At 1: The distance timer will be blocked & DIST will start
but will not perform a Trip command.
Reset to 0: Opto input power off if signal assigned to an
opto input
OR DDB at 0 if signal assigned to a DDB cell
Reset all CB monitoring lockout (all counters and values
are reset ('CB condition')
Reset all values of CB monitoring (all counters and
values are reset ('CB condition')
Reset all permanent alarms + LEDs and relays are
lached
Enable I>4 Element for stub bus protection (isolator of
HV line open - status isolator must be connected to an
opto input)
Internal input for trip logic A
Set to 1: Trip A Internal input managed with the general
trip logic(with A/R / Evolving fault...)
Can be assigned by external condition
Internal input for trip logic B
Set to 1: Trip B Internal input managed with the general
trip logic(with A/R / Evolving fault...)
Can be assigned by external condition
Internal input for trip logic C
Set to 1: Trip C Internal input managed with the general
trip logic(with A/R / Evolving fault...)
Can be assigned by external condition
Zero Sequence Power - Timer Block: If assigned to an
opto input in a dedicated PSL, Zero Sequence Power
function will start, but will not perform a trip command -
the associated time-delay (adjusted with 'K Time Delay
Factor ' setting, will be blocked
PAP (specific application) Carrier Receive for
teletransmission
PAP (specific application) Carrier Out of Service (DT trip
decision)
Timer Block for frosen every timer initiated with PAP
(specific application) function
Reset Thermal Overload Protection
External time synchronisation input
Select Check synchro for NCIT
Timer block T1 input
Timer block T2 input
Timer block TZp input
Timer block TZq input
Timer block T3 input
Timer block T4 input
Timer block underfrequency stage 1
Timer block underfrequency stage 2
Timer block underfrequency stage 3
Timer block underfrequency stage 4
Timer block overfrequency stage 1
Timer block overfrequency stage 2
Block phase undercurrent stage 1
Block phase undercurrent stage 2
Timer block phase undercurrent stage 1
Programmable Logic
MiCOM 40 Agile P442, P444
Source
PSL (IN)
Distance
PSL (IN) CB
Monitoring
PSL (IN) CB
Monitoring
PSl (IN)
PSL (IN)
PSL (IN) Trip
Logic
PSL (IN)
Trip Logic
PSL (IN)
Trip Logic
PSL (IN)
ZSP
PSL(IN)
PSL(IN)
PSL(IN)
PSL(IN)
PSL(IN)
PSL
PSL
PSL
PSL
PSL
PSL
PSL
PSL (IN)
PSL (IN)
PSL (IN)
PSL (IN)
PSL (IN)
PSL (IN)
PSL (IN)
PSL (IN)
PSL (IN)

Advertisement

Table of Contents
loading

This manual is also suitable for:

P442P444

Table of Contents