For internal distribution only
On the HiPath 1190/1190R
Installation Procedures
Step
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
Procedure
Turn off the power supply.
Remove the system's front cover.
Remove the system's back cover.
Move the module's latch as shown in Figure 4-14.
Insert the module into one of the slots shown in Table 4-3.
Move the module's latch back to secure module.
Connect the Main Distribution Frame cables as follows: For modules allo-
cated to the system's bottom slots (slots 1 to 10) use the bottom opening
(see Figure 4-12). For modules allocated to the system's top slots (slots
11 to 20) route the cables through the top anchors (see Figure 4-13).
Connect to the appropriate module connectors (see "Expansion Module
(EB)" on page 3-16).
Attach cables to anchors using plastic brackets.
"Performing a Visual Inspection" on page 4-48.
Reassemble the entire set.
Turn on the power supply.
Configure the required data (see "Operation" on page 6-1).