TME1 module display readings
Display
E
Continuous
8
Continuous
Continuous
P
Continuous
A
Continuous
I
Continuous
3
Continuous
7
Continuous
F
Continuous
o
Continuous
3
Cycle - Live
f e
Alternating
h
Continuous
A.
Continuous
A31003-K1250-S100-12-7619
HiPath 1100, Service Manual
Reading
Waits 10 seconds for a command from the software (Hi-
Path 1100 E1 Trunk Manager). If it receives no command af-
ter the specified time, the system resumes its usual oper-
ation.
Transferring memory contents to DRAM memory.
Checking and validating contents of Flash memory.
TME1 module is active but CAS link is out of service.
TME1 module is active with CAS link.
"Unpacking" HiPath E1 Trunk Manager.
Writing software to Flash memory.
Checking transferred data.
E1 and CAS links are still out of service; the reason is un-
known.
Clearing Flash memory.
Flash memory cleared.
No software in Flash memory. Waiting for Tool to download
software
Module is working as a Master and synchronizing TME1
modules.
Option Modules (MO)
Meaning
Modules
3-33