For internal distribution only
The time count starts upon connection of a call and will never restart while the call is
in progress (e.g., when there is a transfer). Once the time expires, the call is termi-
nated.
Activate/Deactivate timer for outgoing external calls (048)
Activate/Deactivate the timer for a specified extension.
Second Attendant for MSN (082)
This setting specifies a timeout after which calls start ringing at an extension.
Modem Extension (085)
This setting specifies the extension where the modem is connected.
MSN and Extension Assignment (086)
This setting assigns extensions to each MSN to be transmitted to the outgoing calls
destination.
External-to-External Transfer (091)
This feature allows a specified extension to transfer an external call (incoming or out-
going) to another external call.
An External-to-External transfer can only be made when at least one of the lines is
a digital line.

7.2.4 DISA

This setting allows you to make an external call from an external telephone (as if it
was an extension) through your system. In addition, the following features can be ac-
tivated or deactivated: Call Forwarding, Feature Deactivation, Conference, Night Ser-
vice, Suffix-Dialing, Door Opener, Electronic Lock, Individual Speed Dialing, System
Speed Dialing, Relay, and Do Not Disturb.
Only one external call can be made or one feature can be used at a time. After suc-
cessful activation of a feature, the call is immediately terminated. In the case of a
call, it is terminated right after a caller hangs up.
TAPI only monitors physical ports. To operate correctly, a DISA feature must use
special ports, and those cannot be monitored. If a physical port is used when the
DISA feature is active, the TAPI will be able to monitor it.
DISA Permission (018)
Activates the DISA feature.