Configuring the System Specifically for the Client
Comments about the System's Programming Codes
If the option "Detect all slots" is selected, the system will detect the components in
the following order:
1 - External lines/digital extensions
2 - External lines/analog extensions
This means that if there was a previous configuration in which the order of analog
lines/extensions was specified, that order will be changed when a TME1 or S0 mod-
ules is added to the system.
Example: In a HiPath 1150 system that has only a MB Module (2 external lines and 10 analog
extensions) the numbering pattern will be 801 and 802 for the external analog lines, and 11 to
20 for the analog extensions. The insertion of a S0 module produces the following configura-
tion:
- 801 to 805 for the external digital lines
- 806 and 807 for the external analog lines
- 11 to 15 for the ISDN extensions
- 16 to 25 for analog extensions
- Extension 16 as the Programming extension.
If "Detect only specified slot" is selected, the existing numbering configuration will
remain. Only the module will be detected by the system.
Type of MSN Signal (073)
This setting specifies the selection of one of four different ring signals to be assigned
to registered MSNs.
Reference Clock (090)
This allows you to specify a module slot for the system's Reference Clock.
Assigning a Temporary MSN (093)
This feature allows you to use a temporary MSN from your own directory to make an
external call. Or, to use the "Key Assignment" feature to assign a key to a MSN for
monitoring incoming and outgoing calls (see Key Assignment - Using a Temporary
MSN for Making a Call, in the User Manual).