General Technical Data, Pm230, Ip55 - Siemens SINAMICS G120 Operating Instructions Manual

Low voltage converters built-in and wall mounting units with cu230p-2 control units
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

10.3.2

General technical data, PM230, IP55

Property
Line voltage
Output voltage
Input frequency
Output frequency
Power factor λ
Line impedance
Inrush current
Pulse frequency (factory set‐
ting)
Braking methods
Degree of protection IP55
Rated short-circuit current
Converter with the CU230P-2 Control Units
Operating Instructions, 09/2017, FW V4.7 SP9, A5E34257946B AE
Version
380 ... 480 V 3 AC ± 10%
0 V 3 AC ... input voltage x 0.95 (max.)
50 Hz ... 60 Hz, ± 3 Hz
0 Hz ... 550 Hz, depending on the control mode
0.9
Uk ≤ 1%, no line reactor permitted
Low LO base load input current
4 kHz
The pulse frequency can be increased in 2 kHz steps up to 16 kHz (up to 8 kHz for 75 kW and
90 kW). An increase in the pulse frequency results in a lower output current.
DC braking
To comply with this degree of protection requires the following:
● Operation with operator panel or dummy cover
● Connections for control cables are made properly using EMC cable glands.
Restrictions for special ambient conditions (Page 510)
When fused using a type J or 3NE1 fuse, rated voltage 480 VAC
with the rated current of the specific inverter.
FSA ... FSC: 40 kA
FSD ... FSF: 65 kA
10.3 Technical data, PM230 Power Module
Technical data
441