cfgChassisDynamicPSUEngagementEnable (Read or Write)
Enables or disables dynamic engagement.
Description
•
0 — Disabled
Legal Values
•
1 — Enabled
Default
0
cfgChassisAllow110VACOperation (Read or Write)
Description
Enables or disables normal chassis power allocations when any PSU is connected to 110V AC service. If
disabled and 110V power supplies are detected, all subsequent server power allocation requests are denied. In
this mode more servers cannot be powered on, regardless of server priority.
•
0 — Disabled
Legal Values
•
1 — Enabled
0
Default
cfgChassisAllow110VACOperationTimestamp (Read Only)
Description
The timestamp recorded when Allow110V setting from power management is enabled.
Legal Values
Default
0
cfgChassisMaxPowerConservationMode (Read or Write)
Enables or disables maximum power conservation mode. When enabled, all servers are immediately reduced to
Description
their minimum power levels, and all subsequent server power allocation requests are denied. In this mode,
performance of powered on servers may be degraded and more servers cannot be powered on, regardless of
server priority.
•
0 — Disabled
Legal Values
•
1 — Enabled
Default
0
cfgChassisMaxPowerConservationModeTimestamp (Read Only)
The timestamp recorded when maximum power conservation mode is enabled.
Description
Legal Values
0
Default
cfgChassisPerformanceOverRedundancy (Read or Write)
Enables or disables server performance over power redundancy. When enabled, this option favors server
Description
performance and server power-up over maintenance of power redundancy. When disabled, the system favors
power redundancy over server performance. If the power supply in the chassis does not provide sufficient