Cfglannetworking; Cfgnicipv4Enable (Read Or Write) - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

# idRacBuildInfo=200708301525
# idRacName=CMC-1
racadm getconfig -g idRacInfo
# idRacType=16
# idRacProductInfo=Integrated Dell Remote Access Controller
# idRacDescriptionInfo=This system component provides a complete set of remote management
functions for Dell PowerEdge Servers
# idRacVersionInfo=1.06.06
# idRacBuildInfo=15
# idRacName=idrac-GSRS3V1

cfgLanNetworking

This group contains parameters to configure CMC NIC for IPv4.
One instance of the group is allowed. Some objects in this group may require CMC NIC to be reset, which may cause a brief loss in
connectivity. Objects that change CMC NIC IP address settings close all active user sessions and require users to reconnect using
the updated IP address settings.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
NOTE: You can configure a setting that does not have a hash sign (#) prefixed in the output. To modify a configurable
object, use the —o option.
The following sections provide information about the objects in the cfgLanNetworking group.

cfgNicIPv4Enable (Read or Write)

Enables or disables IPv4 stack.
Description
1 (TRUE)
Legal Values
0 (FALSE)
0
Default
cfgNicVLanEnable (Read or Write)
Enables or disables the VLAN capabilities.
Description
All chassis management traffic, including the CMC and all iDRACs, resides on this external VLAN when enabled.
No iDRAC configuration change is required to use this external management network VLAN.
1 (TRUE)
Legal Values
0 (FALSE)
0
Default
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
Example
1
racadm config -g cfgLanNetworking -o cfgNicVLanEnable
0
81

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents