PWR
PWR
PWR
PWR
<senType>
Cable
Cable
getslotname
Displays the name and host name (if available) of all 16 slots, or of a specified slot (the slot number is indicated)
Description
in the chassis. Optionally, this command can be used to find if the slot name or host name is displayed in the
CMC User Interface or with the getslotname —i <slotNum> command. If the host name is not available,
the static slot name is used.
To use this subcommand, you must have the CMC Login User privilege.
•
Synopsis
racadm getslotname
•
racadm getslotname -i <slotNum>
•
racadm getslotname -h <enabled>
•
racadm getslotname — Displays the slot name for all 16 slots in the chassis.
Input
•
-i <slotNum> — specifies the ID of the slot.
Legal values: 1–16
•
-h <enabled> — Specifies whether to use the slot name or the host name (if available).
1= use host names, 0=use slotnames
Example
•
Displays the slot name for all 16 slots in the chassis
racadm getslotname
<Slot #> <Slot Name>
1
SLOT-01
2
Webserver01
3
Webserver3
4
SLOT-04
5
SLOT-05
6
SLOT-06
7
SLOT-07
8
SLOT-08
9
SLOT-09
10
SLOT-10
11
SLOT-11
12
SLOT-12
13
SLOT-13
14
SLOT-14
15
SLOT-15
16
SLOT-16
racadm getslotname -i 1
SLOT-01
52
3
4
5
6
<Num>
1
2
<Host name>
WXP-8GRB221
WXP-319QWEecet5
PS-3
PS-4
PS-5
PS-6
<sensorName>
IO-Cable
FPC-Cable
Online
Slot Empty
Failed
Slot Empty
<status>
OK
OK
OK
N/A
OK
N/A