Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected between system
BIOS in slot 4 and CMC.
Display specific module log:
racadm getactiveerrors -m server-1

getarraycfg

To display the storage array properties and configuration status, run this command.
Description
getarraycfg -m <module> [-s]
Synopsis
-m — The valid value for —m <module> is server–<n>, where n = 1 to 7 and 9 to 15.
Input
-s — Query for current storage configuration process status.
Output
Array configured properties for:
Member Name
Member IP
Group Name
Group IP
Fabric Selection
<module> configuration completed successfully.
Get the configured storage array properties from server–3.
Example
racadm getarraycfg -m server-3
Query for current storage configuration process status on server–3.
racadm getarraycfg -m server-3 -s

getassettag

Description
Displays the asset tag for the chassis.
To run this subcommand, you must have the CMC Login User privilege.
racadm getassettag [-m <module>]
Synopsis
Input
-m <module> — Specifies the module whose asset tag you want to view.
Legal value: chassis
Display asset tag for chassis
Example
racadm getassettag -m chassis
racadm getassettag
chassis 78373839–33