Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected between system
BIOS in slot 4 and CMC.
•
Display specific module log:
racadm getactiveerrors -m server-1
getarraycfg
To display the storage array properties and configuration status, run this command.
Description
getarraycfg -m <module> [-s]
Synopsis
•
-m — The valid value for —m <module> is server–<n>, where n = 1 to 7 and 9 to 15.
Input
•
-s — Query for current storage configuration process status.
Output
Array configured properties for:
•
Member Name
•
Member IP
•
Group Name
•
Group IP
•
Fabric Selection
<module> configuration completed successfully.
•
Get the configured storage array properties from server–3.
Example
racadm getarraycfg -m server-3
•
Query for current storage configuration process status on server–3.
racadm getarraycfg -m server-3 -s
getassettag
Description
Displays the asset tag for the chassis.
To run this subcommand, you must have the CMC Login User privilege.
racadm getassettag [-m <module>]
Synopsis
Input
-m <module> — Specifies the module whose asset tag you want to view.
Legal value: chassis
•
Display asset tag for chassis
Example
racadm getassettag -m chassis
•
racadm getassettag
chassis 78373839–33
29