power, both for redundancy, as well as full performance, then some servers may not grant sufficient power for
full performance. In order to maintain redundancy, It may not be powered on.
Legal Values
0 — Disabled
1 — Enabled
Default
1
cfgChassisInMaxPowerCapacity (Read Only)
Indicates the total chassis power budget (in watts) available for chassis operation.
Description
None
Legal Values
None
Default
cfgChassisInRedundancyReserve (Read Only)
Indicates the amount of redundant power (in watts) in reserve that can be utilized in the event if an AC grid or
Description
PSU is unsuccessful. This value is0 if the Redundancy Policy is set to 0 (no redundancy).
0 (disabled)
Legal Values
1 (enabled)
None
Default
cfgChassisInPowerServerAllocation (Read Only)
Indicates (in watts) the cumulative power allocated to servers. There is no default as this parameter is specific
Description
to the particular customer configuration.
None
Legal Values
None
Default
cfgChassisInfrastructureInPowerAllocation (Read Only)
Indicates the estimated cumulative DC output power consumption (in watts), determined from a field
Description
replaceable unit (FRU) on the hardware modules in the chassis.
None
Legal Values
None
Default
cfgChassisTotalInPowerAvailable (Read Only)
Indicates the amount of power (in watts) available for use by the chassis.
Description
None
Legal Values
None
Default