Racresetcfg - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

racadm racreset
Output
RAC reset operation initiated successfully. It may take up to a minute for
the RAC to come online again.
To reset CMC.
Example
racadm racreset
To reset server 1
racadm racreset -m server-1
To reset servers 1 and 3
racadm racreset -m server-1 -m server-3

racresetcfg

Deletes your current CMC configuration and resets CMC to the factory default settings. After reset, the
Description
default name and password are root and calvin, respectively, and the IP address is 192.168.0.120.
If you run racresetcfg from a network client (for example, a supported web browser, Telnet or SSH, or
Remote RACADM), use the default IP address. The racresetcfg subcommand does not reset the
cfgDNSRacName object.
To run this subcommand, you must have the Chassis Administrator privilege.
Synopsis
racadm racresetcfg
RAC reset operation initiated successfully. It may take several minutes
for the RAC to come online again.
racadm racresetcfg [-m <module>] [-c <feature>]
-m <module> — Specifies the device to reset the configuration on <module>. <module> must be one
Input
of the following values:
– chassis — Default state if -m is not specified
– server–<n> — where n=1–16
– server–<nx> — where n=1–8; x=a, b, c, d (lower case)
– kvm
-c <feature> — Must be one of the following values:
– ad — Reset Active Directory properties to default (default is disabled).
– pcap — Reset Power Cap to default.
– flex — Reset flexaddress properties to default (default is disabled).
– dpse — Reset Dynamic Power Supply Engagement to default (default is disabled).
Reset the KVM configuration on CMC.
Example
racadm racresetcfg -m kvm
62
NOTE: Certain firmware processes must be stopped and restarted to complete the reset to defaults.
CMC becomes unresponsive for about 30 seconds while this operation completes.
NOTE: There is a 100 percent fan request when the command is issued against the servers.
NOTE: FlexAddress or FlexAddressPlus will be set to enabled on running racadm racresetcfg
(default is enabled without –c option). The server must be turned off prior to running this command
to change the slot state.
NOTE: -c option is valid with <module = chassis> only.
NOTE: If chassis is the target of racresetcfg, CMC resets after the operation.