Dell PowerEdge M1000e Reference Manual page 95

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

The following sections provide information about the objects in the cfgSerial group.
cfgSerialBaudRate (Read or Write)
Sets the baud rate on the serial port.
Description
2400, 4800, 9600, 19200, 28800, 38400, 57600,115200
Legal Values
115200
Default
cfgSerialConsoleEnable (Read or Write)
Enables or disables the serial console interface.
Description
1 (TRUE)
Legal Values
0 (FALSE)
1
Default
cfgSerialConsoleQuitKey (Read or Write)
This key or key combination terminates the Virtual Console text for CMC .
Description
Legal value:
String of up to 4 characters
This key specifies the character that ends the serial text console connect (or racadm connect) command.
For example, striking both the CTRL key and the \ key simultaneously (rather than sequentially) is denoted as ^
\.
Configuration options: The value must start with the ^ character, and must follow one of the characters — a-z,
A-Z, [,], \
Default:
^\
cfgSerialConsoleIdleTimeout (Read or Write)
The maximum number of seconds to wait before an idle serial session is disconnected.
Description
0 = No timeout
Legal Values
60–1920
1800
Default
NOTE: The CTRL key is represented by using the ^ (carat) character.
NOTE: The CTRL key does not generate a character by itself, but must be struck simultaneously with
another key to generate a character.
NOTE: For more information about running the RACADM commands for special characters, see
Guidelines to Quote Strings Containing Special
Characters.