Deploy - Dell PowerEdge M1000e Reference Manual

Chassis management controller version 5.0 for dell poweredge m1000e racadm command line
Hide thumbs Also See for PowerEdge M1000e:
Table of Contents

Advertisement

-b — Connects to the switch or console using the binary mode. -b is an optional; a server or a switch must be
Input
present.
-m <module> — Must be one of the following values:
server –<n> — where n=1–16
server –<nx> — where n=1–8; x = a, b, c, d (lower case)
switch –<n> — where n = 1 to 6 or <a1 | a2 | b1 | b2 | c1 | c2>
Connect to I/O Module 1 serial console:
Example
racadm connect -m switch-1
Connect to server 1 serial console:
racadm connect -m server-1

deploy

Description
Deploys blade server or IOM by specifying the required properties.
To use this subcommand, you must have the Server Administrator privilege.
Synopsis
racadm deploy -m server-<n> -u root -p <password> -s <ipaddress> <subnet>
<gateway> -b <device> -o no | yes
racadm deploy -m server-<n> -u root -p <password>-s
<prefixlen>
where <prefixlen> must be a number between 0 and 128.
racadm deploy -m server-<n>
racadm deploy -m switch-<n> -u root -p <password>
racadm deploy -m switch-<n> -v
racadm deploy -a [server/switch] -u root -p <password>
racadm deploy -q [-n <numofblades>]
—b <device> — Specifies the first boot device must be used with -o. Use with-m <module> to
Input
specify for an individual server, or with an -a for all servers.
Legal values are: None, PXE, HDD, CD-DVD, vFDD, vCD-DVD, iSCSI, SD, FDD, RFS.
-o no/yes — Indicates if the server must start from the device once. Use this option with -b option.
Use with -m <module> to specify for an individual server, or with -a for all servers.
-a — server/switch. Applies options to all modules present in the chassis of the given module type.
Specify the value as server or switch. Default value is server. Switches must support Ethernet
Management.
-u <username> — Indicates that the <password> is supplied for the root user on the server or
switch. Root is a constant parameter, the only value that is valid with the —u option.
—m <module> — Specifies the server or switch you want to configure.
Legal values:
– server-<n>, where n=1–16
– server-<nx>, where n=1– 8; x = a,b,c,d (lower case)
– switch-<n>, where n=1– 6
-p <password> — Specifies the password for the root user on the server or switch. For switches, valid
passwords are 6–32 ASCII characters in length, ranging in value 32–125 (decimal). For servers, valid
passwords are 1–20 ASCII characters in length, ranging in value 32–126 (decimal).
NOTE: If you use the -b option, reset the CMC to end the connect operation.
NOTE: Use setniccfg to configure static IP address, subnet mask, and gateway, and DHCP, speed and
duplex properties.
<gateway> -b <device>
-o no | yes
-u root -p <password> -d [-6]
SNMPv2 <snmpCommunityString> ro
-6 <ipv6Address>
21