Panasonic LP-310 Operation Manual page 12

Co2 laser marker, lp-300 series
Table of Contents

Advertisement

Power Supply BOX
1. Power Supply Display
• When turning ON the key switch, this indicator flashes in green.
When the system starts up and runs completely, the indicator switches into lighting status.
2. Key Switch
• This key switch is used to start the laser marker system. While the switch is ON, the key cannot be
removed, however, while it is OFF, the key can be removed. Remove the key while not using the laser
marker, and maintain and control the key by the safety controller without fail.
• Since the ON/OFF operation of the key switch makes a load to the laser marker, do not turn OFF the power until
completing the start of the system. Besides, leave an interval for at least 5 seconds from turning OFF the power
to turning ON the power again.
3. Interlock Connector
• This interlock connector controls the deactivating/activating status of the laser. It enables to construct the
interlock system.
Interlock Connector
• This product is equipped with the interlock connector to the power supply box. Use this interlock connector.
On power supply
Interlock Connector: SRCN6A13-3P Japan Aviation Electronics Industry,Ltd.
Connector on the body side: SRCN2A13-3S Japan Aviation Electronics Industry,Ltd.
No.
Signal Name
1
INTERLOCK COM.
2
N.C.
3
INTERLOCK
* Keep the OPEN state between INTERLOCK (Pin 3 ) and INTERLOCK COM. (Pin 1) for 1 sec. or more when they are
oepned. If the OPEN state is too short, the laser tube error (E23) may occurs.
12
1
1
box side
Name
Interlock Common
-
Interlock Input
2
2
2
1
3
3
Common for interlock
Do not connect anything.
When connected to INTERLOCK COM., the product is ready
for laser radiation. When the product is in open status, the
laser radiation is stopped.
3