Adjustment Of Laser Start/End Points - Panasonic LP-310 Operation Manual

Co2 laser marker, lp-300 series
Table of Contents

Advertisement

3-6-4 Adjustment of Laser Start/End Points

Light (shallow)
The depth, shape, visibility, etc. of the marking are changed depending on the type of the target object, scan
speed, laser power, etc.
By using this function, the depth at the start/end points can be reduced and the marking shape can be
adjusted.
Laser start point adjustment
Adjusts the timing for turning on the laser at the start point.
The smaller the value is, the darker (deeper) the marked character at the start point is.
Dark (deep)
50
Setting Range: 50 to 150
Initial Value
Laser end point adjustment
Adjusts the timing for turning off the laser at the end point.
The larger the value is, the darker (deeper) the marked character at the end point is.
Light (shallow)
50
Setting Range: 50 to 150
Initial Value
128
Proper
Light (shallow)
150
: 100
Proper
Dark (deep)
150
: 100
Proper
Dark (deep)