Timing Chart

Basic I/O
OFF
Key Switch
ON
OFF
Head display panel
ON
OFF
Radiation Display
ON
OFF
READY Output
ON
OFF
File Selection Input
ON
OFF
TRIG Input
ON
OPEN
Manual Shutter
CLOSE
OFF
Laser Radiation
Stop Input
ON
OFF
Alarm Output
ON
*1: For the file selct input in I/O, if a value of 1 to 120 is selected, the selected file No. is displayed.
If a value other than 1 to 120 is selectd, '---' is displayed.
Input TRIG. IN with holding the input status of the file selection (D0 to D6). (When the file No.
changing command (FNO) is set by RS-232C, input of D0 to D6 is not required.)
CHECK
To reset the alarm status, reboot the laser marker by turning the key switch.
Item
Time
T1
Approx. 0.5 sec.
T2
Approx. 15 sec.
T3
1ms or more
T4
10ms or more
T5
within 5ms
164
File No.
Error No.
Display
Display
Rotation
888
Display
T1
Light in
Light in blue
red
T2
System check time
Disables to perform marking after approx. 15 seconds from the start of the
laser pump.
Set the marking trigger to ON when passing 1ms or more after switching the
file.
Keep ON state for 10ms or more.
Time from inputting the trigger to the start of the actual marking.
File No.
Display
File No. Display
*1
Light in
Light in blue
red
Start
End Marking
Marking
T5
T3
T4
Remarks
Error No.
File No.
Display
Display
Light in
Light in blue
red
Start
Stop Laser
Marking
T5
T3
T4