Troubleshooting

If any operation errors occur, check items below first.
When the problems cannot be resolved by following the below measures, please contact us.
Troubles
Power supply is not
turned on.
The guide laser does
not light.
Data cannot be
marked.
188
Possible Causes
Power cable is not connected. Connect the power cable.
Power cable is not plugged
in outlet
The shutter lever is not set
to the guide laser side.
The marking start command
is not input.
The distance to the work
has not been calibrated.
Laser power and scan
speed are not appropriate
to the marking target
object.
The trigger signal is kept
ON.
The manual shutter is
closed (in remote mode).
The laser radiation stop
input of the I/O connector
is OFF.
The interlock of the power
supply BOX is removed.
Measures
Insert the plug in the socket.
Set the shutter lever to the guide laser side.
Input the marking start command.
Calibrate the distance to the work.
Raise the laser power or lower the scan speed. Or
perform both of them.
Since the trigger signal sensitive to the edge, input the
edge.
Open the manual shutter.
Turn ON the laser radiation stop input from the I/O
connector.
Attach the optional interlock connector.
Ref.
Page
40
40
134
-
54
126
164
43
13
12