I/O Connector
• This product is equipped with the laser radiation stop input in the I/O connector.
Lase r Marker Side Co nne ctor Type
User Side Co nnector Ty pe
* As a user side connector, following items are attached to this product.
[Attached i te m] User Si de Con nector
[Attached i te m] User Si de Con nector C over
Laser Radiation Stop Input
• When changing the status of both laser radiation stop input (Pin 4) and output common (Pin 15) into open
status, the laser radiation is stopped and the marking is invalid.
When performing marking, connect both laser radiation stop input (Pin 4) and output common (Pin 15).
• This product is not activated by connecting
LASER STOP
CHECK
Connecting Sample (In case of operating only laser marker)
Interlock Input Terminal
(Power Supply BOX)
I/O Connector
* Example when only the file No. 1 is used. To change the files, connect the pin No. 5 to 8 and 18 to 20 (D0 to D6) to the
external control device.
Pin 4
Laser Radiation Stop Input
: F emale D-sub 2 5 pin
: Male D -su b 25 pin *
(Pin 4) terminals of the I/O connector.
1. INTERLOCK COM.
3. INTERLOCK
1. +12V
2. 0V
3. TRIG. IN
4. LASER STOP
14. IN COM.
15. OUT COM.
: HDBB-25 P (Hi ro se El ectoric C o., Ltd.)
: HDB-CT F (Hirose Ele c to ri c Co ., Ltd .)
IN COM.
(Pin 14),
OUT COM.
(Pin 15), and
To Emergency
Stop Switch
12V
To Sensor
0V
To Manual Door