Panasonic LP-310 Operation Manual page 18

Co2 laser marker, lp-300 series
Table of Contents

Advertisement

Applicable Standards
This product is applied the following standards. When the system is exported as a single unit or a part mounted on other
machines or equipment, prior to exporting, make sure that the system may meet the requirement of the standards in countries
or regions where the system is to be exported.
Model
JIS (Japanese Industrial Standards)
LP-310
JIS C 6802: 2014 "Safety of laser products"
FDA (Food and Drug Administration) Regulations
LP-310-A
21 CFR1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50
"PART 1040 PERFORMANCE STANDARDS FOR LIGHTEMITTING PRODUCTS"
EN Standard (CE Marking) *1
2014/30/EU "EMC Directive"
EN55011: 2009+A1: 2010 "Industrial, scientific and medical equipment. Radio-frequency disturbance
characteristics. Limits and methods of measurement"
EN61000-6-2: 2005 "Electromagnetic compatibility (EMC). Generic standards. Immunity for industrial
environments"
2014/35/EU "Low Voltage Directive"
EN60204-1: 2006+A1: 2009 "Safety of machinery. Electrical equipment of machines. General
requirements"
(partially applied *2) EN61010-1: 2010 "Safety requirements for electrical equipment for measurement,
control, and laboratory use. General requirements"
LP-310-C
EN60825-1: 2014 "Safety of laser products. Equipment classification and requirements"
2011/65/EU "RoHS Directive"
EN 50581:2012 "Technical documentation for the assessment of electrical and electronic products with
respect to the restriction of hazardous substances"
KC mark (Korea Certification)
Class A Equipment (Industrial Broadcasting & Communication Equipment)
This equipment is Industrial (Class A) electromagnetic wave suitability equipment and seller or user
should take notice of it, and this equipment is to be used in the places except for home.
A 급 기기 ( 업무용 방송통신기자재 )
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자는 이 점을 주의하시기 바라며 , 가정외의
지역에서 사용하는 것을 목적으로 합니다 .
*1:Contact for CE:
Panasonic Marketing Europe GmbH, Panasonic Testing Center
Winsbergring 15, 22525 Hamburg, Germany
*2:Although EN 60204-1 is applied as a harmonized standard of LVD, EN 61010-1 is partially applied to enhance the
conformity with electrical safety and requirement of LVD.
Other Cautions
1. Prior to wiring and/or cable connecting work, ensure that all the power has been turned off.
2. Use the accessory cables attached to the system for connecting cables without fail.
3. Be sure that the supplied power does not exceed the rating. Prior to turning the power on, check any change
in voltage.
4. If a surge occurs in the power supplied, connect a surge absorber to a source of the surge to absorb it.
5. Make sure to ground a terminal of a frame ground (F.G.) of the system when using the device caused the
noise around this product.
6. Install such that the housing of the power supply box and that of the head are at the same electric potential.
7. Since the ON/OFF operation of the key switch makes a load to the laser marker, do not turn OFF the power
until completing the start of the system. Besides, leave an interval for at least 5 seconds from turning OFF the
power to turning ON the power.
8. Note that the marked characters may be blurred if a CD cleaner or other liquid gets on the marked surface of
the attached CD-ROM "LP-310 Setting Software".
18
Applicable standards and regulations