Fujitsu ETERNUS DX60 S3 User Manual page 177

Disk storage systems, all-flash arrays
Hide thumbs Also See for ETERNUS DX60 S3:
Table of Contents

Advertisement

Chapter 3 Component Status
3.24 Port Detail
-
Serial Number
The serial number of the port is displayed.
If the serial number cannot be acquired, a "-" (hyphen) is displayed.
-
Hardware Revision
The hardware version of the port is displayed.
If the hardware version cannot be acquired, a "-" (hyphen) is displayed.
-
SFP Type
The SFP type of the port is displayed. If the SFP is not installed, "Unmount" is displayed.
SFP+(SMF)
8G LongWave
SFP+(MMF)
8G SFP+
16G SFP+(SMF)
16G LongWave
16G SFP+(MMF)
16G SFP+
Unknown
SFP type other than above
-
Temperature
The real time temperature of the SFP in the port is displayed in Celsius (C) and in Fahrenheit (F).
When the information cannot be obtained, a "-" (hyphen) is displayed.
x C / y F (x: -128.00 to 128.00, y: -198.40 to 262.40)
-
Voltage
The real time voltage of the SFP in the port is displayed.
When the information cannot be obtained, a "-" (hyphen) is displayed.
x V (x: 0.00 to 6.55)
-
Current
The real time current of the SFP in the port is displayed.
When the information cannot be obtained, a "-" (hyphen) is displayed.
x mA (x: 0.00 to 131.00)
-
TX Power
The real time transmission power of the SFP in the port is displayed.
When the information cannot be obtained, a "-" (hyphen) is displayed.
x mW (x: 0.00 to 6.55)
-
RX Power
The real time received power of the SFP in the port is displayed.
When the information cannot be obtained, a "-" (hyphen) is displayed.
x mW (x: 0.00 to 6.55)
"Temperature", "Voltage", "Current", "TX Power", and "RX Power" are displayed as the CM#x CA#y port infor-
mation in
"3.8 Channel Adapter Detail" (page
ETERNUS Web GUI User's Guide (Operation)
Copyright 2016 FUJITSU LIMITED
132). In this screen, "Sensor Information" is displayed.
177
P2X0-1260-19ENZ0

Hide quick links:

Advertisement

Table of Contents
loading