Pre-Transfer Charging Assembly; Before Removing Pre-Transfer Charging Assembly; Removing Pre-Transfer Charging Assembly; Photosensitive Drum - Canon imageRUNNER 5065 series Service Manual

Table of Contents

Advertisement

[3]
[4]
When replacing the primary charging wire or the primary charging assem-
bly, be sure to execute the following in the service mode to clean the wire:
COPIER > FUNCTION > CLEANING > WIRE-CLN.
Further, be sure to use a strengthened polishing pad (blue holder) as the
cleaning pad.

7.10.4 Pre-Transfer Charging Assembly

7.10.4.1 Before Removing Pre-Transfer Charging
Assembly
iR5065 / iR 5055 / iR5075 / / /
1) Detach the front cover. (page 10-11)Reference[Removing the Front
Cover]
2) Detach the toner supply cover. (page 10-12)Reference[Removing the
Toner Supply Cover]
3) Remove the primary fan duct. (page
Primary fan Duct]

7.10.4.2 Removing Pre-Transfer Charging Assembly

iR5065 / iR 5055 / iR5075 / / /
1) Remove the pre-transfer charging assembly [3].
- 1 connector [1]
- 1 screw [2]
Be sure to execute the wire cleaning in the user mode after mounting the pre-
transfer charging assembly.

7.10.5 Photosensitive Drum

7.10.5.1 Points to Note When Handling Photosensitive
Drum
iR5065 / iR 5055 / iR5075 / / /
The machine's photosensitive drum is made of high-sensitivity amorphous
silicon, and its sensitivity can start to deteriorate depending on how and
where it is placed, requiring the following:
[1] Whenever the process unit is removed from the machine or the
photosensitive drum is removed from the process unit, be sure to protect
the photosensitive drum against light. Wrap 6 or more sheets of A3 or
larger paper around the photosensitive drum.
[2] Do not place the process unit or the photosensitive drum in a area subject
to the direct rays of the sun.
[3] Do not place the process unit or the photosensitive drum in an area
[1]
[2]
F-7-43
10-27)Reference[Removing
[2]
[3]
[1]
F-7-44
subject to high or low temperature or humidity or where temperature or
humidity tends to change rapidly.
[4] Do not place the process unit or the photosensitive drum in an area
subject to dust, ammonium gas, or organic solvent/gas.
The foregoing requirements commonly apply to all photosensitive drums.

7.10.5.2 Before Removing Photosensitive Drum

iR5065 / iR 5055 / iR5075 / / /
1) Detach the front cover. (page 10-11)Reference[Removing the Front
Cover]
2) Detach the toner supply cover. (page 10-12)Reference[Removing the
Toner Supply Cover]
3) Remove the primary fan duct. (page
Primary fan Duct]
4) Remove the developing assembly. (page 7-27)Reference[Removing
Developing Assembly]
5) Remove the process unit. (page 7-19)Reference[Removing Process
Unit]
6)
Remove
the
20)Reference[Removing Primary Charging Assembly]
7)
Remove
the
21)Reference[Removing Pre-Transfer Charging Assembly]
8) Remove the potential sensor unit. (page 7-30)Reference[Removing
Potential Sensor Unit]

7.10.5.3 Removing Photosensitive Drum

iR5065 / iR 5055 / iR5075 / / /
1) Remove the potential sensor rail stay [2].
- 2 screws [1]
0015-4879
[1]
0015-4880
2) Remove the gear plate [2].
- 3 screws [1]
[2]
3) Remove the front side stay [2].
- 2 screws [1]
[1]
0015-4881
4) Remove the photosensitive drum by holding it as indicated.
10-27)Reference[Removing
primary
charging
assembly.
pre-transfer
charging
assembly.
[2]
F-7-45
[1]
[1]
F-7-46
[2]
[1]
F-7-47
Chapter 7
0015-6503
(page
7-
(page
7-
0015-4888
[1]
7-21

Advertisement