9.2.2 30-Sec Start-Up Mode
iR5065 / iR 5055 / iR5075 / / /
<Conditions of Use>
When all the following conditions exist:
- the environment temperature is 17 deg C or higher.
- the site is a low-humidity environment (absolute moisture content is 13 g or less)
- the temperature of the fixing roller is 70 deg C or less
<Characteristics>
The target temperature of the fixing roller is 205 deg C.
However, the machine shifts to standby mode regardless of whether the temperature of the fixing roller reaches the target or not when 29.5 sec passes after power-on.
[1] Fixing roller 1/4-speed rotation
[2] Fixing roller 1/1-speed rotation

9.2.3 Low-Temperature Environment Start-Up Mode

iR5065 / iR 5055 / iR5075 / / /
<Conditions of Use>
When all the following conditions exit:
- the environment temperature is lower than 17 deg C
- the temperature of the fixing roller is 70 deg C or lower
<Characteristics>
- The target temperature for the fixing roller is 215 deg C.
- If all the following conditions exist, the machine shifts to standby mode:
the temperature of the fixing roller has reached the target temperature.
potential control has ended
- The machine takes 75 sec or less to move from power-on to standby states. (reference only)
9-4
Description
When all the following conditions exist:
- the environment temperature is 17 deg C or higher
- the site is a low-humidity environment
- the temperature of the fixing roller is 70 deg C or lower
When all the following conditions exist:
- the site is a high-humidity environment
- the temperature of the fixing roller is 70 deg C or lower
This mode is used when all the following conditions exist:
- the site is in a high humidity environment.
- the temperature of the fixing roller is 70 deg C or lower.
The temperature of the fixing roller is 70 deg C or higher.
To limit power consumption, the target temperature is decreased at specific time intervals after the end of
start-up.
To limit power consumption, the target temperature is decreased.
To limit power consumption, the target temperature is decreased at specific time intervals after the end of
start-up.
To limit power consumption, the target temperature is decreased at specific time intervals after the end of
start-up.
None
To enhance fixing, the machine changes the start-up sequence and the control temperature.
To ensure fixing on heavy paper, the machine changes the target temperature and copying/printing speed.
To ensure fixing on transparencies, the target temperature is increased.
To ensure fixing for bond paper, machine increases the target temperature in a low-temperature
environment while decreasing the copying/printing speed.
POWER ON
(deg c)
250
200
[1]
150
100
50
0
0
5
10
T-9-4
STANDBY
[2]
15
20
25
30
35
F-9-6
40
45
50
(sec)
0015-4586
0015-4587