Chapter 12
Content of transmission
Transmission of alert code
Jam
Alarm
Error
Confirmation whether there is processing that e-
RDS executes

12.1.7 Resend at SOAP transmission error

iR5065 / iR 5055 / iR5075 / / /
When SOAP send error is generated by the trouble on UGW side etc. at the transmission of an alert code, the latest three batches of data that failed in the transmission
are stored in HDD, and e-RDS resends it at prescribed intervals.

12.1.8 e-RDS setting screen

iR5065 / iR 5055 / iR5075 / / /
The e-RDS setting screen is in the service mode screen.
When the tab above is selected on any e-RDS setting screen, it changes to the mid item screen. Moreover, it returns to previous screen when reset key is pressed.
Menu Screen
Setting screen of e-RDS. The form and the initial value of each setting item are as follows.
Item(meaning)
E-RDS
(Embedded-RDS)
RGW-ADR
(RDS-Gateway ADDRESS)
RGW-PORT
(RDS-Gateway PORT)
COM-TEST
(Communication Test)
12-2
Transmission timing
When the state of the device is changed.
When Jam occurs
When Alarm occurs
When Error occurs
Every 6 hours
F-12-1
Explanation
Turning OFF/ON e-RDS. 0:OFF / 1:ON
Counter information and error information are transmitted to the host at ON.
Initial value: 0: OFF
URL of the host (When the input area is selected (touched), shift to the keyboard screen)
Initial value: URL of an actual host.
Length: 129 characters (NULL is contained)
Port Number of the host
Initial value: 443
Range of available number: 1-65535
Execution of Communication test
Communication test starts when you select (touch) this and press the [OK] key.
e-RDS tries the connection with the host, and displays the result by "OK!" or "NG!". (NG: No Good, the
communication test is failed)