Siemens SITRANS P Brochure & Specs page 104

Measuring instruments for pressure
Table of Contents

Advertisement

SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure, flow and level
DS III series for absolute pressure
(from differential pressure series)
Selection and Ordering data
Further designs
Add "-Z" to Order No. and specify Order
code.
2
Pressure transmitter with mounting
bracket made of:
• Steel
• Stainless steel
O-rings for process flanges
(instead of FPM (Viton))
• PTFE (Teflon)
• FEP (with silicone core, approved for food) A21
• FFPM (Kalrez, compound 4079)
• NBR (Buna N)
Plug
• Han 7D (metal, gray)
• Han 8U (instead of Han 7D)
Sealing screws
¼-18 NPT, with valve in material of process
flanges
Cable sockets for M12 connectors (metal)
Rating plate inscription
(instead of German)
• English
• French
• Spanish
• Italian
English rating plate
Pressure units in inH
2
Quality inspection certificate (Factory cali-
bration) to IEC 60770-2
Acceptance test certificate
To EN 10204-3.1
Factory certificate
To EN 10204-2.2
"Functional Safety (SIL)" certificate
"PROFIsafe" certificate and protocol
Setting of upper limit of output signal to
22.0 mA
Manufacturer's declaration acc. to NACE
(only together with seal diaphragm made of
Hastelloy and stainless steel)
Type of protection IP68
(not together with Han 7D/Han 8U plug,
cable gland PG 13.5)
Digital indicator alongside the input keys
(only together with the devices 7MF4333-
....2-.A.6 or -.A.7-Z, Y21 or Y22 + Y01)
Supplied with oval flange
(1 item), PTFE packing and stainless steel
screws in thread of process flange
Use in or on zone 1D/2D
(only together with type of protection "Intrinsic
safety (EEx ia)")
Use on zone 0
(only together with type of protection "Intrinsic
safety (EEx ia)")
Oxygen application
(max. 120 bar a (1740 psi a) at 60°C (140 °F)
with oxygen measurement and inert liquid)
Explosion-proof "Intrinsic safety" to
INMETRO (Brazil)
(only for transmitter 7MF4...-.....-.B..)
2/104
Siemens FI 01 · 2009
Order code
HART PA
A01
A02
A20
A22
A23
A30
A31
A40
A50
B11
B12
B13
B14
B21
O or psi
C11
1)
2)
C12
C14
C20
C21
D05
D07
D12
D27
F)
D37
E01
E02
E10
E25
© Siemens AG 2008
Selection and Ordering data
FF
Further designs
Add "-Z" to Order No. and specify Order
code.
Explosion-proof "Intrinsic safety" to NEPSI
(China)
9 9
9 9
9 9
(only for transmitter 7MF4...-.....-.B..)
9 9
9 9
9 9
Explosion protection "Explosion-proof" to
NEPSI (China)
(only for transmitter 7MF4...-.....-.D..)
9 9
9 9
9 9
Explosion-proof "Zone 2" to NEPSI (China) E57
9 9
9 9
9 9
(only for transmitter 7MF4...-.....-.E..)
9 9
9 9
9 9
Interchanging of process connection side H01
9 9
9 9
9 9
Vent on side for gas measurements
9 9
Process flange
9 9
• Hastelloy
• Monel
9 9
9 9
9 9
• Stainless steel with PVDF insert
max. PN 10 (MWP 145 psi),
max. temperature of medium 90 °C (194 °F)
9 9
9 9
9 9
For ½-14 NPT inner process connection on
the side in the middle of the process flange,
vent valve not possible
9 9
9 9
9 9
Additional data
9 9
9 9
9 9
Add "-Z" to Order No. and specify Order
9 9
9 9
9 9
code.
9 9
9 9
9 9
Measuring range to be set
9 9
9 9
9 9
Specify in plain text (max. 5 digits):
Y01: ... up to ... mbar, bar, kPa, MPa, psi
9 9
9 9
9 9
Measuring point number (TAG No.)
Max. 16 characters, specify in plain text:
9 9
9 9
9 9
Y15: ...........................................
Measuring point text
9 9
9 9
9 9
Max. 27 characters, specify in plain text:
Y16: ...........................................
Entry of HART address (TAG)
9 9
Max. 8 characters, specify in plain text:
9 9
Y17: ...........................................
9 9
Setting of pressure indication in pressure
units
9 9
9 9
9 9
Specify in plain text (standard setting: mA):
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
9 9
9 9
9 9
bar, mbar, mm H
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
2
kg/cm
, Torr, ATM oder %
9 9
9 9
9 9
*) ref. temperature 20 °C
Setting of pressure indication in
non-pressure units
9 9
9 9
9 9
Specify in plain text:
Y22: ..... up to ..... l/min, m
(specification of measuring range in pressure
units "Y01" is essential, unit with
9 9
9 9
9 9
max. 5 characters)
Preset bus address
(possible between 1 and 126)
9 9
9 9
9 9
Specify in plain text:
Y25: .....................
Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset
9 9
9 9
9 9
9 9 = available
1)
When the manufacture's certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
9 9
9 9
9 9
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
2)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
F) Subject to export regulations AL: 9I999, ECCN: N.
Order code
E55
E56
H02
K01
K02
K04
Y01
Y15
Y16
Y17
Y21
*)
*)
*)
O
, inH
O
, ftH
O
,
2
2
2
2
,
Y22 +
Y01
3
/h, m, USgpm, ...
Y25
HART PA
FF
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9
9 9

Advertisement