Siemens SITRANS P Brochure & Specs page 12

Measuring instruments for pressure
Table of Contents

Advertisement

SITRANS P measuring instruments for pressure
Transmitters for gage, absolute and differential pressure
SITRANS P250 for differential pressure
Overview
2
SITRANS P250 transmitter for differential pressure
The SITRANS P250 transmitter measures the differential pres-
sure of liquids and gases.
Benefits
• High measuring accuracy
• Sturdy stainless steel enclosure
• For aggressive and non-aggressive media
• For the measurement of the differential pressure of liquids and
gases
• Temperature-compensated measuring cell
• Compact design
Application
The SITRANS P250 transmitter for differential pressure is prima-
rily used in the following industries:
• Chemical industry
• Pharmaceutical industry
• Food industry
• Mechanical engineering
• Shipbuilding
• Water supply
Design
Main components:
• Stainless steel enclosure with piezo-resistive ceramic measur-
ing cell and (temperature-compensated) electronics module.
• Process connection made of stainless steel in diverse designs
(see Selection and ordering data)
• Electrical connection through connectors acc. to EN 175301-
803-A and round connectors M12, as well as with permanently
fixed cable
Function
The pressure transmitter measures the differential pressure of
liquids and gases.
2/12
Siemens FI 01 · 2009
© Siemens AG 2008
Mode of operation
p
p
1
2
SITRANS P250 pressure transmitter, function diagram
The piezo-resistive ceramic measuring cell (membrane) has a
Wheatstone bridge circuit, on which the operating pressure P1
and P2 of the media acts at both ends.
The voltage output from the measuring cell is converted by an
amplifier into an output current of 4 to 20 mA or an output voltage
of 0 to 5 or 10 V DC.
The output current and voltage are linearly proportional to the in-
put pressure.
Technische Daten
SITRANS P250 differential pressure transmitter
Application
Differential pressure transmitter
Mode of operation
Measuring principle
Input
Measured variable
Measuring range
Operating pressure
Burst pressure
Output
Output signal
• Current output signal
• Voltage output signal
Load
3-wire
2-wire
Measuring accuracy
Dynamic behavior (at 25°C (77°F),
including conformity error, hystere-
sis and repeatability)
Long-term drift acc. to IEC 60770
Influence of ambient temperature
• Start of scale
• Full-scale value
Dynamic behavior
Response time T
99
Load variation
U
const.
U
I
, U
I
0
B
Liquids and neutral gases
Piezo-resistive measuring cell
(ceramic diaphragm)
Differential pressure
0 ... 0.1 to 0 ... 25 bar
(0 ... 1.45 to 0 ... 363 psi)
≤ 25 bar (363 psi) at a differential
pressure range < 6 bar (87 psi)
≤ 50 bar (725 psi) at a differential
pressure range > 10 bar (145 psi)
1.5 x operating pressure
4 ... 20 mA
0 ... 5 V and 0 ... 10 V DC
> 10 kΩ
≤ (U
- 11 V) / 0.02 A
H
≤ 1 % of typical full-scale value,
see "Measuring range" table
≤ 0.5 % of full-scale value/year
≤ 0.6 %/10 K of full-scale value
(≤ 1.2 %/10 K for measuring cell
0 ... 0.1 bar (1.45 psi))
≤ 0.22 %/10 K of full-scale value
(≤ 0.37 %/10 K for measuring cell
0 ... 0.1 bar (1.45 psi))
Suitable for static and dynamic
measurements
< 5 ms
< 50 Hz

Advertisement

Table of Contents