Siemens SITRANS P Brochure & Specs page 58

Measuring instruments for pressure
Table of Contents

Advertisement

SITRANS P measuring instruments for pressure
Transmitters for gage pressure for the paper industry
SITRANS P300 with PMC connection
Technical specifications
SITRANS P300 for gage pressure with PMC connection for the paper industry
Input
2
Measured variable
Spans (infinitely adjustable) or
nominal measuring range and
max. permissible test pressure
Lower measuring limit
• Measuring cell with silicone oil
Upper measuring limit
• Measuring cell with silicone oil
Output
Output signal
Physical bus
With polarity reversal protection
Electrical damping T
63
Accuracy
Reference conditions
(All error data refer always refer to the set
span)
Measurement deviation with cut-off point set-
ting, including hysteresis and repeatability.
Linear characteristic curve
• r
10
• 10 < r
30
• 30 < r
100
Settling time T
without electrical damping
63
Long-term drift at 30 °C ( 54 °F)
Influence of ambient temperature
• at -10 ... +60 °C (14 ... 140 °F)
• at -40 ... -10 °C and +60 ... +85 °C
(-40 ... 14 °F and 140 ... 185 °F)
Influence of the medium temperature (only
with front-flush diaphragm)
• Temperature difference between medium
temperature and ambient temperature
Rated operating conditions
Installation conditions
Ambient temperature
• Measuring cell with silicone oil
• Digital display
• Storage temperature
Climatic class
Condensation
Degree of protection to EN 60529
Electromagnetic compatibility
• Emitted interference and interfer. immunity
2/58
Siemens FI 01 · 2009
HART
Gage pressure (flush-mounted)
Span
0.01 ... 1 bar g
(0.15 ... 14.5 psi g)
0.04 ... 4 bar g
(0.58 ... 58 psi g)
0.16 ... 16 bar g
(2.3 ... 232 psi g)
Depending on the process connection, the span
may differ from these values
100 mbar a (1.45 psi a)
100% of max. span
4 ... 20 mA
-
No
(step width 0.1 s)
Set to 0.1 s (0 ... 100 s)
To EN 60770-1
Increasing characteristic, start-of-scale value 0 bar, stainless steel seal diaphragm, measuring cell
with silicone oil, room temperature 25 °C (77 °F), span ratio (r = max. span/set span)
(0.0029 r + 0.071)%
(0.0045 r + 0.071)%
(0.005 r + 0.05)%
Approx. 0.2 s
(0.25 r)%/5 years
(0.1 r + 0.2)%
(0.1 r + 0.15)%/10 K
3 mbar/10 K (0.04 psi/10 K)
Observe the temperature class in areas subject to explosion hazard.
-40 ... +85 °C (-40 ... +185 °F)
-30 ... +85 °C (-22 ... +185 °F)
-50 ... +85 °C (-58 ... +185 °F)
Permissible
IP65, IP68, NEMA X, enclosure cleaning, resistant to lyes, steam to 150° C (302 °F)
To EN 61326 and NAMUR NE 21
© Siemens AG 2008
Max. perm. test pres-
sure
6 bar g
(87 psi g)
10 bar g
(145 psi g)
32 bar g
(464 psi g)
PROFIBUS PA
Nominal measuring
Max. perm. test pres-
range
sure
1 bar g
6 bar g
(14.5 psi g)
(87 psi g)
4 bar g
10 bar g
(58 psi g)
(145 psi g)
16 bar g
32 bar g
(232 psi g)
(464 psi g)
Depending on the process connection, the nomi-
nal measuring range may differ from these values
100% of the max. nominal measuring range
Digital PROFIBUS PA signal
IEC 61158-2
Yes
0,075%
0.25%/5 years
0,3%
0.25%/10 K