Transmitters for gage, absolute and differential pressure, flow and level
Selection and Ordering data
SITRANS P pressure transmitters for absolute
pressure, from the pressure series DS III HART
Measuring cell filling
Measuring cell
cleaning
Silicone oil
Standard
1)
Inert liquid
Grease-free
Span
8.3 ... 250 mbar a
(0.12 ... 3.63 psi a)
43 ... 1300 mbar a
(0.62 ... 18.9 psi a)
0.16 ... 5 bar a
(2.32 ... 72.5 psi a)
1 ... 30 bar a
(14.5 ... 435 psi a)
Wetted parts materials
Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
2)3)4)
Version for diaphragm seal
Process connection
• Connection shank G½B to EN 837-1
• Female thread ½-14 NPT
• Oval flange made of stainless steel
7
- Mounting thread
/
-20 UNF to EN 61518
16
- Mounting thread M10 to DIN 19213
• Male thread M20 x 1,5
• Male thread ½-14 NPT
Non-wetted parts materials
• Housing made of die-cast aluminium
• Housing stainless steel precision casting
Version
• Standard version
• International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
• Without
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
6)
- "Explosion-proof (EEx d)"
- "Intrinsic safety and explosion-proof enclosure
7)
(EEx ia + EEx d)"
- "
"
Ex nA/nL (zone 2)
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
7)
Zone 1D/2D)"
• With FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof
6)
(is + xp)"
Electrical connection / cable entry
8)
• Screwed gland Pg 13.5
• Screwed gland M20x1.5
• Screwed gland ½-14 NPT
• Han 7D plug (plastic housing) incl. mating
8)
connector
9)
• Plug M12 (metal)
© Siemens AG 2008
SITRANS P measuring instruments for pressure
Order No.
7 M F 4 2 3 3 -
F)
-
7 7 7 7 7
7 7 7 7
1
3
D
F
G
H
A
B
C
Y
0
1
2
3
5
6
0
5)
3
1
2
A
B
D
P
E
R
N C
A
B
C
D
F
DS III series for absolute pressure
(from gage pressure series)
Selection and Ordering data
SITRANS P pressure transmitters for absolute
pressure, from the pressure series DS III HART
Display
• Without indicator
• Without visible digital indicator (digital indicator
hidden, setting: mA)
• With visible digital indicator
• With customer-specific digital indicator (setting
as specified, Order code "Y21" or required)
Power supply units
see "SITRANS I power supply units and isolation
amplifiers".
Factory-mounting of shut-off valves and valve manifolds see page
2/142.
Included in delivery of the device:
• Brief instructions (Leporello)
• CD-ROM with detailed documentation
1)
For oxygen application, add Order code E10.
2)
Version 7MF4233-1DY... only up to max. span 200 mbar a (2.9 psi a)
3)
When the manufacture's certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
4)
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
5)
Not together with Electrical connection „Screwed gland Pg 13.5" and
„Han7D plug".
6)
Without cable gland, with blanking plug.
7)
With enclosed cable gland EEx ia and blanking plug.
8)
Not together with type of protection "Explosion-proof" and type of protection
"Ex nA".
9)
Not together with types of protection "Explosion-proof" or "Intrinsic safety
and explosion-proof"
F) Subject to export regulations AL: 9I999, ECCN: N.
Order No.
7 M F 4 2 3 3 -
F)
-
7 7 7 7 7
7 7 7 7
0
}
1
6
7
Siemens FI 01 · 2009
2/93