Siemens SITRANS P Brochure & Specs page 95

Measuring instruments for pressure
Table of Contents

Advertisement

Transmitters for gage, absolute and differential pressure, flow and level
Selection and Ordering data
Further designs
Add "-Z" to Order No. and specify Order
code.
Pressure transmitter with mounting
bracket made of:
• Steel
• Stainless steel
Plug
• Han 7D (metal, gray)
• Han 8U (instead of Han 7D)
Cable sockets for M12 connectors (metal)
Rating plate inscription
(instead of German)
• English
• French
• Spanish
• Italian
English rating plate
Pressure units in inH
O or psi
2
Quality inspection certificate (Factory cali-
1)
bration) to IEC 60770-2
2)
Acceptance test certificate
To EN 10204-3.1
Factory certificate
To EN 10204-2.2
"Functional Safety (SIL)" certificate
"PROFIsafe" certificate and protocol
Setting of upper limit of output signal to
22.0 mA
Manufacturer's declaration acc. to NACE
Type of protection IP68
(not together with Han 7D / Han 8U plug,
Pg 13.5 screwed gland)
Digital indicator alongside the input keys
(only together with the devices 7MF4233-
....0-.A.6 or -.A.7-Z, Y21 or Y22 + Y01).
Supplied with oval flange
(1 item), PTFE packing and screws in thread
of oval flange
Use in or on zone 1D/2D
(only together with type of protection "Intrinsic
safety (EEx ia)")
Use on zone 0
(only together with type of protection "Intrinsic
safety (EEx ia)")
Oxygen application
(max. 120 bar a (1740 psi a) at 60 °C (140 °F)
with oxygen measurement and inert liquid)
Explosion-proof "Intrinsic safety" to
INMETRO (Brazil)
(only for transmitter 7MF4...-.....-.B..)
Explosion-proof "Intrinsic safety" to NEPSI
(China)
(only for transmitter 7MF4...-.....-.B..)
Explosion protection "Explosion-proof" to
NEPSI (China)
(only for transmitter 7MF4...-.....-.D..)
Explosion-proof "Zone 2" to NEPSI (China) E57
(only for transmitter 7MF4...-.....-.E..)
© Siemens AG 2008
SITRANS P measuring instruments for pressure
Order code
Selection and Ordering data
HART PA
FF
Additional data
Add "-Z" to Order No. and specify Order
code.
Measuring range to be set
Specify in plain text (max. 5 digits):
9 9
9 9
9 9
A01
Y01: ... up to ... mbar, bar, kPa, MPa, psi
9 9
9 9
9 9
A02
Measuring point number (TAG No.)
Max. 16 characters, specify in plain text:
9 9
Y15: ...........................................
A30
9 9
A31
Measuring point text
9 9
9 9
9 9
Max. 27 characters, specify in plain text:
A50
Y16: ...........................................
Entry of HART address (TAG)
Max. 8 characters, specify in plain text:
9 9
9 9
9 9
B11
Y17: ...........................................
9 9
9 9
9 9
B12
9 9
9 9
9 9
Setting of pressure indication in pressure
B13
units
9 9
9 9
9 9
B14
Specify in plain text (standard setting: mA):
9 9
9 9
9 9
B21
Y21: mbar, bar, kPa, MPa, psi, ...
Note:
The following pressure units can be selected:
9 9
9 9
9 9
C11
bar, mbar, mm H
mmHG, inHG, psi, Pa, kPa, MPa, g/cm
9 9
9 9
9 9
C12
kg/cm
*) ref. temperature 20 °C
9 9
9 9
9 9
C14
Setting of pressure indication in
non-pressure units
Specify in plain text:
9 9
C20
Y22: ..... up to ..... l/min, m
9 9
C21
(specification of measuring range in pressure
units "Y01" is essential, unit with
9 9
D05
max. 5 characters)
Preset bus address
9 9
9 9
9 9
D07
(possible between 1 and 126)
9 9
9 9
9 9
D12
Specify in plain text:
Y25: .....................
Only "Y01", "Y21", "Y22", "Y25" and "D05" can be factory preset
9 9
9 9
9 9
D27
9 9 = available
1)
9 9
9 9
9 9
D37
2)
9 9
9 9
9 9
E01
9 9
9 9
9 9
E02
9 9
9 9
9 9
E10
9 9
9 9
9 9
E25
9 9
9 9
9 9
E55
9 9
9 9
9 9
E56
9 9
9 9
9 9
DS III series for absolute pressure
(from gage pressure series)
*)
*)
*)
O
, inH
O
, ftH
O
2
2
2
2
, Torr, ATM oder %
3
/h, m, USgpm, ...
When the manufacture's certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
Order code
HART PA
FF
9 9
Y01
9 9
9 9
9 9
Y15
9 9
9 9
9 9
Y16
9 9
Y17
9 9
9 9
9 9
Y21
,
2
,
9 9
9 9
9 9
Y22 +
Y01
9 9
Y25
Siemens FI 01 · 2009
2/95