Siemens SITRANS P Brochure & Specs page 59

Measuring instruments for pressure
Table of Contents

Advertisement

SITRANS P300 for gage pressure with PMC connection for the paper industry
Medium conditions
Process temperature
• Measuring cell with silicone oil
Design
Weight (without options)
Housing material
Material of parts in contact with the medium
• Seal diaphragm
• Measuring cell filling
Power supply U
H
Terminal voltage on transmitter
Separate power supply
Bus voltage
• Without EEx
• For intrinsically-safe operation
Current consumption
• Max. basic current
• Startup current
basic current
• Max. fault current in the event of a fault
Fault disconnection electronics (FDE)
Certificate and approvals
Classification according to pressure equip-
ment directive (DRGL 97/23/EC)
Explosion protection
Intrinsic safety "i"
Identification
Permissible ambient temperature
• Temperature class T4
• Temperature class T5
• Temperature class T6
Connection
Effective inner capacitance:
Effective inner inductance:
Explosion protection to FM for USA and
Canada (cFM
)
US
• Identification (DIP) or (IS); (NI)
• Identification (DIP) or (IS)
© Siemens AG 2008
SITRANS P measuring instruments for pressure
Transmitters for gage pressure for the paper industry
HART
-40 ... +100 °C (-40 ... +212 °F)
Approx. 1 kg (2.2 lb)
Stainless steel, mat. No. 1.4301/304
Hastelloy C276, mat. No. 2.4819
Silicone oil
10.5 ... 42 V DC
for intrinsically safe operation: 10.5 ... 30 V DC
-
-
-
-
-
-
-
For gases of fluid group 1 and liquids of fluid group 1; complies with requirements of Article 3, para-
graph 3 (sound engineering practice)
PTB 05 ATEX 2048
Ex II 1/2 G EEx ia/ib IIB/IIC T4, T5, T6
-40 ... +85 °C (-40 ... +185 °F)
-40 ... +70 °C (-40 ... +158 °F)
-40 ... +60 °C (-40 ... +140 °F)
To certified intrinsically-safe circuits with maxi-
mum values:
U
= 30 V, I
= 100 mA,
i
i
P
= 750 mW, R
= 300
i
i
C
= 6 nF
i
L
= 0.4 mH
i
Certificate of Compliance 3025099
CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; CL I, ZN 0/1 AEx ia IIC T4 ... T6;
CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
Certificate of Compliance 3025099C
CL I, DIV 1, GP ABCD T4 ... T6; CL II, DIV 1, GP EFG; CL III; Ex ia IIC 4 ... T6;
CL I, DIV 2, GP ABCD T4 ... T6; CL II, DIV 2, GP FG; CL III
SITRANS P300 with PMC connection
PROFIBUS PA
Supplied through bus
Not necessary
9 ... 32 V
9 ... 24 V
12.5 mA
Yes
15.5 mA
Available
To certified intrinsically-safe circuits with maxi-
mum values:
FISCO supply unit:
U
= 17.5 V, I
= 380 mA, P
= 5.32 W
i
i
i
Linear barrier:
U
= 24 V, I
= 250 mA, P
= 1.2 W
i
i
i
C
= 1.1 nF
i
L
7 H
i
Siemens FI 01 · 2009