Siemens SITRANS P Brochure & Specs page 75

Measuring instruments for pressure
Table of Contents

Advertisement

Transmitters for gage, absolute and differential pressure, flow and level
Selection and Ordering data
SITRANS P pressure transmitters for gage
pressure
DS III PA (PROFIBUS PA) series
DS III FF series (FOUNDATION Fieldbus)
Measuring cell filling
Measuring cell
cleaning
Silicone oil
Standard
1)
Inert liquid
Grease-free
Nominal measuring range
1 bar g
(14.5 psi g)
4 bar g
(58 psi g)
16 bar g
(232 psi g)
63 bar g
(914 psi g)
160 bar g
(2320 psi g)
400 bar g
(5802 psi g)
700 bar g
(10153 psi g)
Wetted parts materials
Seal diaphragm
Process connection
Stainless steel
Stainless steel
Hastelloy
Stainless steel
Hastelloy
Hastelloy
2) 3)
Version as diaphragm seal
Process connection
• Connection shank G½A to EN 837-1
• Female thread ½-14 NPT
• Oval flange made of stainless steel
7
- Mounting thread
/
-20 UNF to EN 61518
16
- Mounting thread M10 to DIN 19213
- Mounting thread M12 nach DIN 19213
• Male thread M20 x 1,5
• Male thread ½-14 NPT
Non-wetted parts materials
• Housing made of die-cast aluminium
• Housing stainless steel precision casting
Version
• Standard version
• International version, English label inscriptions,
documentation in 5 languages on CD
Explosion protection
• Without
• With ATEX, Type of protection:
- "Intrinsic safety (EEx ia)"
4)
- "Explosion-proof (EEx d)"
- "Intrinsic safety and explosion-proof enclosure
5)
(EEx ia + EEx d)"
- "Ex nA/nL (zone 2)"
- "Intrinsic safety, explosion-proof enclosure and
dust explosion protection (EEx ia + EEx d +
6)
Zone 1D/2D)"
(not for DS III FF)
• With FM + CSA, Type of protection:
- "Intrinsic safety and explosion-proof
5)
(is + xp)"
Electrical connection / cable entry
• Screwed gland M20x1.5
• Screwed gland ½-14 NPT
6)
• Plug M12 (metal)
© Siemens AG 2008
SITRANS P measuring instruments for pressure
Order No.
Selection and Ordering data
SITRANS P pressure transmitters for gage
pressure
7 M F 4 0 3 4 -
DS III PA (PROFIBUS PA) series
7 M F 4 0 3 5 -
DS III FF series (FOUNDATION Fieldbus)
7 7 7 7 7
-
7 7 7 7
Display
• Without indicator
1
• Without visible digital indicator (digital indicator
3
• With visible digital indicator
• With customer-specific digital indicator (setting
B
C
D
Factory-mounting of shut-off valves and valve manifolds see page
2/142.
E
The device is delivered together with brief instructions (Leporello) and a
F
CD-ROM containing detailed documentation.
G
J
1)
2)
A
3)
B
C
Y
4)
5)
6)
0
1
2
3
4
5
6
0
3
1
2
A
B
D
P
E
R
N C
B
C
F
hidden, setting: mA)
as specified, Order code "Y21" or required)
For oxygen application, add Order code E10.
When the manufacture's certificate M (calibration certificate) has to be
ordered for transmitters with diaphragm seals, it is recommended only to
order this certificate exclusively with the diaphragm seals. The measuring
accuracy of the total combination is certified here.
Whe the acceptance test certificate 3.1 for transmitters with direct-con-
nected diaphragm seals is ordered, this certificate must also be ordered
with the corresponding seals.
Without cable gland, with blanking plug.
With enclosed cable gland EEx ia and blanking plug.
Cannot be used together with the following types of protection:
"Explosion-proof" and "Intrinsic safety and explosion-proof"
DS III series
for gage pressure
Order No.
7 M F 4 0 3 4 -
7 M F 4 0 3 5 -
7 7 7 7 7
-
7 7 7 7
0
}
1
6
7
Siemens FI 01 · 2009
2/75
2