C80 Series Connection and Setup Manual
9 GOT Initial Setup
(5) Select "Write Data" and "Destination Drive" and then click [GOT Write] button.
When writing the package data, open the Application Selection setting dialog and confirm that the following
recommended settings are selected for the Application Selection.
How to display the Application Selection dialog:
Click "Write Option" to open the Write dialog and then click "Application Selection".
<Recommended setting>
- PLC program monitor: PLC program monitor (R Ladder) [01.18.000] or later
- Backup and restore [01.16.000] or later
- CNC monitor 2
SVGA : [01.16.000] or later
VGA : [01.18.000] or later
- GOT platform library [01.16.000] or later
- GOT extended function library [01.18.000] or later
Select the other functions than the above as required.
(Note) If OS data and project data (drawing data) are larger than the capacity of built-in flash memory, select "A:
Standard SD card" for "Drive" to store the project data in an SD card.
Confirm that a SD card is inserted on the GOT rear slot when selecting "A: Standard SD card".
IB-1501452-C
130