12 Setting Machine Parameters

12.7 Servo Simplified Adjustment

12.7.1 First Measure Against Vibration

Setting the filter can reduce the vibration.
(1) Select [Drv mon] and then [Servo unit] on the Diagn screen. See the displayed value in "AFLT frequency".
(Note)
(2) Select [Param] and then [Servo param] on the Mainte screen. Set the AFLT frequency value you saw at (1) to
"#2238 SV038 FHz1 (Notch filter frequency 1)".
(Note)
If the vibration is not reduced by the measure, refer to the manuals of the drive unit you are using.
The screen above is when NC parameters have default values.
The screen above is when NC parameters have default values.